Section 4: System Operation
When armed:
This feature provides a means to exit the premises while the alarm system is armed without having to disarm then rearm it.
Pressing [*][0] starts a 2-minute timer that enables any door programmed as a delay zone to be opened and closed once
without triggering an alarm.
If the door is not closed at the end of the 2-minute timer, the entry delay sequence begins. Any additional activity on another
zone triggers the associated alarm or delay sequence.
4.8 SMS Command and Control
The user can perform certain functions on the alarm panel by remote using SMS text messages. In addition, the system
sends SMS messages to the user to confirm commands . SMS programming options are accessed through programming
section [851].
The security system only responds to SMS messages sent from designated phone numbers (programmed in section [851]>
[311]-[342]).
For more information on SMS command and control, and for a complete listing of communicator programming options, refer
to the alternate communicator installation manual.
4.8.1 SMS Command and Control Functions
The following alarm system functions are controllable via SMS:
l Stay arm the system
l Away arm the system
l Night arm the system
l Disarm the system
l Activate/deactivate command output 1-4
l System status request
l Alarm memory request
l Zone bypass
l Zone unbypass
SMS text messages must be formatted as follows:
<function name><space><partition #><space><access code>
e.g., Stay Arm partition 1 1234
Once the command is received and executed by the alarm system, the user receives a confirmation text message.
Note: Do not use Away Arm if Push to Set [001][072] or Final Door Set [001][016] zones are programmed.
4.9 Visual Verification
This feature enables the central station operator to view captured images of the premises in the event of an alarm event.
Combination camera/motion detectors can be installed throughout the premises to provide visual verification coverage. The
microphone on the camera PIR can be disabled.
Visual verification sessions are triggered by the following:
l Fire key
l Medical key
l Panic key
l Alarms detected by armed PIRCameras
To set up video verification on a partition:
l Enroll the camera PIR; [804]
l Set video verification options; [804]>[841]:
l [001] Visual Verification Enable/Disable
l [002] View Time Window
l [003] View Other Alarms
l Input a custom label to identify the camera PIR; [000]>[001]
l Enable this option on the alternate communicator (section [10] option 2).
Refer to the Camera PIR installation manual for more details.
- 54 -

Table of Contents

Other manuals for DSC HS2016

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC HS2016 and is the answer not in the manual?

DSC HS2016 Specifications

General IconGeneral
Mounting TypeWall mount
Power Supply16.5VAC
Battery Backup12VDC
Operating Temperature32°F to 120°F (0°C to 49°C)
Dimensions267mm