Appendix 7: Specifications
Zone Configuration
l 16, 32, 64, or 128 wireless zones supported and up to 8 hardwired zones available on the controller
l 40 zone types and 14 programmable zone attributes
l Zone configurations available: normally closed, single EOL and DEOL supervised
l Hardwired zone expansion (fully supervised) available using the model HSM2108 (eight zone expander module)
l Wireless zone expansion (fully supervised) available using the HSM2Host 2-way wireless integration module oper-
ating at 915MHz (North America), 433MHz (Europe) and 868MHz (international)
Access Codes
l Up to 1002 access codes: 1000 (level 2-EN), one installer code (level 3-EN), and one maintenance code
l Programmable attributes for each user code (see "Access Code Attributes" on page 48)
l When using 8-digit access codes, the minimum number of variations are:
HS2016: 2083333
HS2032: 1388888
HS2064/HS2128: 1052631
HS2064 E: 200000
HS2128 E: 100000
Warning Device Output
l Integral sounder capable of 85 dB @ 3m, self-powered type Z
l 2 remote, wireless indoor/outdoor warning devices supported: models PGX901 (indoor), PGX911 (outdoor) (X=4, 8,
or 9)
l Programmable as steady, pulsed or temporal three (as per ISO8201) and temporal four (CO alarm) output
l Warning device sounds alarms in the following priority: fire, CO, burg
Memory
l CMOS EEPROM memory
l Retains programming and system status on AC or battery failure for 20 years min. (not verified by UL)
Power Supply - North America
Transformer: DSC PTD1640U, PTD1640,PTC1640UG
Primary: 120V, 60Hz Class II
Secondary: 16.5VAC, 40VA Max.
Power Supply - International
l Input ratings: 220V-240Vac, 50/60Hz, 200mA
l Transformer required, mounted in the same enclosure, permanently connected
l Transformer secondary ratings: 16.5Vac, 40VA min.
Note: For installations using the transformer mounted inside the cabinet, replace fuse only with the same type (20mm) rated
250V/315mA.
Regulated power supply:
l 1.7A regulated, supervised and integral to the control unit
l Type A as per EN50131-6 Standard
l 700mA auxiliary supply, 12V DC
l Positive temperature coefficient (PTC) for Bell, Aux+ and Battery terminals
l Reverse battery detection/protection
l Supervision for AC power and low battery
l Normal and high current battery charge options
l Supervised battery charging circuit
Current draw (panel):
l 85mA (nominal) 2A(Max)
Bell Output:
l 12V, 700mA supervised (1k Ohm) bell output (current limited at 2 amps)
l Steady, Pulsed, Temporal 3 fire, Temporal 4 CO alarm cadences
l Bell short detection (software + hardware)
Aux+:

Table of Contents

Other manuals for DSC HS2016

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC HS2016 and is the answer not in the manual?

DSC HS2016 Specifications

General IconGeneral
Mounting TypeWall mount
Power Supply16.5VAC
Battery Backup12VDC
Operating Temperature32°F to 120°F (0°C to 49°C)