EasyManuals Logo

DSC LE4000 User Manual

DSC LE4000
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
19
[206] Cellular Receiver 1 Domain Name
Default ( )
Programming this section is not permitted on a UL/ULC listed system.
Enter the Domain Name as 32 ASCII characters. This information is provided by your central
station system administrator.
CELLULAR RECEIVER 2 OPTIONS
[211] Cellular Receiver 2 Account Code
Default (0000000000)
The account code is used by the central station to distinguish between different transmitters.
This account code is used when transmitting signals to the central station receiver. Signals
received on the panel use the panel account number. Valid range: 0000000001 - FFFFFFFFFE.
NOTE: Programming this section as all 0 or F causes a Module Configuration Trouble
(yellow LED = 12 flashes).
[212] Cellular Receiver 2 DNIS
Default (000000)
The DNIS is used in addition to the Account Code to identify the Communicator module at the
central station. Valid range: 000000 - 099999. Values are entered as a 0 followed by the 5-digit
DNIS value. Format is BCD.
NOTE: Each receiver must be programmed with a unique DNIS.
[213] Cellular Receiver 2 Address
Default (000.000.000.000)
Enter the Cellular Receiver 2 IP address. This IP address is provided by your central station.
Format is four fields, each field is 3-digit decimal. Valid range: 000 - 255.
NOTE: When a valid IP address is provided, Cellular Receiver 2 is enabled and
communicates events over the Cellular path.
[214] Cellular Receiver 2 Port
Default (0BF5/3061)
This section defines the port of Cellular Receiver 2. Change the value of this port when your
installation is located behind a firewall, and must be assigned a particular port number, as
determined by your central station system administrator. Valid range: 0000 - FFFF.
NOTE: Do not program Cellular Receiver 1 and Cellular Receiver 2 to communicate to the
same receiver.
[215] Cellular Receiver 2 APN
Default ( )
The APN determines the Cellular network to which the Communicator connects. This
information is available from your network carrier. Program this section with up to 32 ASCII
characters.
NOTE: When a SIM card with a custom APN is used, the unit cannot access the internet. DLS
and remote flash can still be done if section [221] is programmed with a valid Public
APN.
[216] Cellular Receiver 2 Domain Name
Default ( )
Programming this section is not permitted on a UL/ULC listed system.
Enter the Cellular Receiver 2 Domain Name with up to 32 ASCII characters.
CELLULAR OPTIONS
[221] Cellular Public Access Point Name
Default ( )
When the Communicator is operating on a private APN, use this section to select a public
APN for DLS and Remote Firmware Update. This information is available from your network
carrier. The APN identifies the public Cellular network to which the Communicator connects.

Other manuals for DSC LE4000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DSC LE4000 and is the answer not in the manual?

DSC LE4000 Specifications

General IconGeneral
BrandDSC
ModelLE4000
CategoryCell Phone
LanguageEnglish

Related product manuals