42
PC2585 Version
1.1R
[21] Second System Option Code
Page 24
Default Zone Light ON Zone Light OFF
OFF Zone Light 1 TLM disabled TLM enabled
OFF Zone Light 2 TLM trouble sounds bell when armed TLM silent
OFF Zone Light 3 Alarms restore on bell time-out Alarms restoral follows zone restoral
OFF Zone Light 4 Swinger Shutdown resets at 12:00 am Swinger Shutdown resets on arming
ON Zone Light 5 Bell shutdown enabled Bell shutdown disabled
OFF Zone Light 6 Bell output always pulsed Bell output follows zone type
OFF Zone Light 7 Bell output inverted Bell output normal
OFF Zone Light 8 User DLS window enabled User DLS window disabled
[22] Third System Option Code
Page 24
Default Zone Light ON Zone Light OFF
OFF Zone Light 1 PO3: FTC output PO3: Strobe output
OFF Zone Light 2 PO4: TLM and Alarm output PO4: System Status output
OFF Zone Light 3 Hourly Test Transmission Test Transmission as per times in [19] & [32]
OFF Zone Light 4 Test Transmission every 15 minutes Normal Test Transmission
ON Zone Light 5 Bell silent for FTC Bell sounds for FTC
ON Zone Light 6 Downloading Annunciation enabled Downloading Annunciation disabled
ON Zone Light 7 ID Tone/Panel Answer Ack. enabled ID Tone/Panel Answer Ack. disabled
OFF Zone Light 8 2100Hz ID/Panel Answer Ack. Tone 1300Hz ID/Panel Answer Ack. Tone
[23] Fourth System Option Code
Page 25
Default Zone Light ON Zone Light OFF
OFF Zone Light 1 Send Identified Partial Closings Partial Closings not identified
OFF Zone Light 2 Auto-Arm sends Partial Closing Code Auto-Arm does not send Partial Closing Code
ON Zone Light 3 Access Code needed to cancel Auto-Arm Any keypress cancels Auto-Arm
ON Zone Light 4 Access Code needed to bypass zones Access Code not required to bypass zones
OFF Zone Light 5 Master Code not user-programmable Master Code user-programmable
OFF Zone Light 6 One-Time Use Code enabled One-Time Use Code disabled
OFF Zone Light 7 Quick-Exit enabled Quick-Exit disabled
OFF Zone Light 8 SW AUX resets for 5s on Arming SW AUX does not reset on Arming
[24] Fifth System Option Code
Page 25
Default Zone Light ON Zone Light OFF
OFF Zone Light 1 Normally Closed zone loops Double End-of-Line Resistor zone loops
OFF Zone Light 2 Single End-of-Line Resistor Zones Zones use setting in Section [24] Light 1
OFF Zone Light 3 Zones bypassed for 120s on power-up Zones active on power-up
OFF Zone Light 4 Force Arm with AUX zones No Force Arm with AUX zones
OFF Zone Light 5 Home Away Zones have Entry/Exit Delays No Delays for Home Away Zones
OFF Zone Light 6 Bell sounds for [P] Key alarms Bell Silent for [P] Key alarms
ON Zone Light 7 Keypad sounds for [P] Key alarms Keypad silent for [P] Key alarms
OFF Zone Light 8 [F] Key disabled [F] Key enabled