44
[29] Communications Format
Page 28
Default
1 3 Communications Buffer 1
1 3 Communications Buffer 2
[00] Silent Knight / Ademco Slow, 10 BPS, 1400 Hz handshake
[01] Sescoa, Franklin, DCI, Vertex, 20 BPS, 2300 Hz handshake
[02] Silent Knight Fast, 20 BPS, 1400 Hz handshake
[03] Radionics, 40 BPS, 2300/1400 Hz handshake
[04] Radionics, 40 BPS, 2300/1400Hz handshake with parity
[05] Sescoa Super Speed
[06] Silent Knight / Ademco Slow, 10 BPS, 1400 Hz handshake, extended
[07] Sescoa, Franklin, DCI, Vertex, 20 BPS, 2300 Hz handshake, extended
[08] Silent Knight Fast, 20 BPS, 1400 Hz handshake, extended
[09] Radionics, 40 BPS, 2300/1400 Hz handshake, extended
[10] Radionics, 40 BPS, 2300/1400 Hz handshake, with parity, extended
[11] Sescoa Super Speed with identified openings and closings
[12] DTMF Fast, slot programming method
[13] Sur-Gard 4/3 DTMF with parity (2300Hz)
[14] Semadigit DTMF Pager Format
[15] Semaphone Pager
[16] Private Line
[30] Communicator Call Direction Options
Page 31
Default
1 Group A Zone Alarms, Tampers and Restorals
1 Group B Zone Alarms, Tampers and Restorals
1 Group A Access Codes: Openings and Closings
1 Group B Access Codes: Openings and Closings
1 Priority Alarms and Restorals
1 Maintenance Alarms and Restorals
[31] PO1, PO2 and AUX-IN Input Options
Page 31
Default
1 PO1 Output PO1 can control the PC16OUT Module or all PO options described below
9 PO2 Output PO2 can control a Printer or all PO options described below
PO Options
0 Ground Start Pulse
1 Utility Output: [Q][7][1 or 2] with Access Code
2 Strobe Output (Latched Alarm)
3 20-minute Latched Alarm
4 System Status
5 Keypad Buzzer Follow Mode
6 Courtesy Pulse
7 Entry Delay Follower
PC2585 v
1.1R
8 Exit Delay Follower
9 PO Flashes During Exit Delay / PO ON if in Alarm
A PO Flashes During Armed Period
B Kiss-off Output
C Failure to Communicate
D Telephone Line Monitor with Alarm
E Line Seizure Output
F Remote Operation
Enter:
[0] No transmissions for this group
[1] Use Communications Buffer 1 only
[2] Use Communications Buffer 2 only
[3] Use both Communications Buffers
AUX-IN Input Options
Default
0 2 AUX Input
00 Printer Connected to PO2 Enabled
01 Silent 24-hour Zone
02 Audible 24-hour Zone
03 Momentary Contact Arming
04 Blockschloss
05 Push to Set
06 Not Used
07 Forced Answer (for use with Downloading)