23
Example, Option Enabled ‘01’
Printer:
Computer:
Computer message combining for DVACS SIA protocol
Computer message combining when DVACS extended option enabled
NOTE:This will support 0-F group numbers maximum.
[069] TL300 Contact ID Kiss-off Duration
Default: 08
Some control panels may require a different kiss-off duration than the default of 800ms. Program
this option for the duration of the Contact ID kiss off provided to the panel. Each unit has incre-
ments of 100 ms in hex, from 100 ms to a maximum of 8.1 seconds.
For example: 08 = 800 ms
0A = 1000 ms (1 second)
NOTE:Kiss-off durations greater than 1.5 seconds may not be compatible with some alarm panel. This may be
required for special applications. Kiss-off durations higher than 8.1 seconds will not be accurate and may not
match the duration programmed.
[070] TL300 Contact ID Handshake Selection
Default: 2D
1400Hz or Dual tone Handshake can be selected.
Enter “2D” for Dual Tone or Enter 14 for 1400Hz
[071] TL300 Dial Tone Selection
Default: 00
Enter the 2-digit code corresponding to country indicated in the table below.
[072] Heart Beat Interval
This option will control the heart beat interval. Valid entries are 5 to 255 seconds. If an out of
range value is entered, the default heart beat interval will be 10 seconds. Please do not change the
default for UL and ULC installations.
[901] Current T-Link IP Address
The Current T-Link IP Address is a read-only option. If this option is selected through the panel
programming, the T-Link TL250/TL300 module will respond with the current IP address of the
T-Link and display it on the keypad for the user.
01 Nov 2004-11:38:22-01/02-SG -01-1-001--012- Grp 2 Arming!B5
01 Nov 2004-11:38:22-01/02-SG -01-1-001--012- Close User# 01
1011sssssss012sC1s01
1011sssssss012sC2s01
3RRLssssss0AAAOGs002 (partition(OG/CG)
3RRLssssss0AAAOPs001 (user number)
SRRL[#AAAA|Nri2/OP001][14]
Code Country Code Country
00
01
02
03
04
05
06
07
United States/ Canada
The Netherlands
United Kingdom
South Korea
Taiwan
Italy
Brazil
Germany
08
09
0A
0B
0C
0D
0E
0F
Norway
Sweden
Switzerland
Australia
France
Belgium
Future Use
Future Use

Related product manuals