34
NOTE: Uplink cell backup devices send zone 99 for a low battery and a zone 97 for communication failure (no
response from poll). These will report as contact ID E370 (protection loop). let me clarify this: these are sig-
nals GENERATED by the uplink to indicate STATUS of the uplink. The central station will assume that they
were generated by the panel. Additional codes that may be sent would be for zones 81-86 which correspond
to hardwire inputs 1-6. The contact ID message for these is selected by uplink when it is programmed. So,
next time someone reports an unusual zone 97 or 99 being reported to their Central Station, Uplink may be
the culprit. Uplink's number is 1-888-987- 5465 if you need it.
371 Protection Loop Open Trouble-Prot. Loop Open-#
372 Protection Loop Short Trouble-Prot. Loop Short-#
373 FIRE TROUBLE Trouble-Fire Loop-# (Supervision Loss, base tamper, Supervisory open)
374 EXIT ERROR (BY USER) Alarm-Exit Error-#
375 Panic Zone Trouble Trouble-PA Trouble-#
376 Hold-Up Zone Trouble Trouble-Hold-Up Trouble-#
377 Swinger Trouble Trouble – Swinger Trouble-#
378 Cross-zone Trouble Trouble – Cross Zone Trouble - # (restore not applicable)
SENSOR:
380 SENSOR TRBL - GLOBAL Trouble-Sensor Trouble-#
381 LOSS OF SUPERVISION Trouble-RF Sensor Super.-#
382 LOSS OF SUPRVSN Trouble-RPM Sensor Super.-#
383 SENSOR TAMPER Trouble-Sensor Tamper-#
384 RF LOW BATTERY Trouble-RF Sensor Battery-#
385 SMOKE HI SENS. Trouble-Smoke Hi Sens.-#
386 SMOKE LO SENS. Trouble-Smoke Lo Sens.-#
-387 INTRUSION HI SENS. Trouble-Intrusion Hi Sens.-#
-388 INTRUSION LO SENS. Trouble-Intrusion Lo Sens.-# - These codes are similar to those used
for smart smoke detectors. The idea is to report a problem developing
in the detector’s operation.
389 DET. SELF TEST FAIL Trouble-Sensor Test Fail-#
391 Sensor Watch Failure Trouble-Sensor Watch Fail-#
392 Drift Comp. Error Trouble-Drift Comp. Error-# - Reported by Firelite panels. The panel is
not able to adjust its thresholds to balance out drift in the normal oper-
ating point of a smoke detector.
393 Maintenance Alert Trouble-Maintenance Alert-#
OPEN/CLOSE:
400 Open/Close Opening/Closing E = Open, R = Close
401 OPEN/CLOSE BY USER Opening-User # / Closing-User #
402 Group O/C Closing-Group User #
403 AUTOMATIC OPEN/CLOSE Opening-Automatic / Closing-Automatic
404 Late to O/C Opening-Late / Closing-Late
405 Deferred O/C Event & Restore Not Applicable
406 CANCEL (BY USER) Opening-Cancel
407 REMOTE ARM/DISARM Opening-Remote / Closing-Remote
408 QUICK ARM Event Not Applicable for opening / Closing-Quick Arm
409 KEYSWITCH OPEN/CLOSE Opening-Keyswitch / Closing-Keyswitch
435 Second Person Access ACCESS – User #
436 Irregular Access ACCESS – Irregular Access – User #
441 Armed Stay Opening-Armed Stay / Closing-Armed Stay
442 Keyswitch Armed Stay Opening-Keysw. Arm Stay / Opening-Keysw. Arm Stay
450 Exception O/C Opening-Exception / Closing-Exception
451 Early O/C Opening-Early / Closing-Early-User #
452 Late O/C Opening-Late / Closing-Late-User #
453 Failed to Open Trouble-Fail to open (Restore not applicable)
454 Failed to Close Trouble-Fail to Close (Restore not applicable)
455 Auto-Arm Failed Trouble-Auto Arm Failed (Restore not applicable)
456 Partial Arm Closing-Partial arm-User #
457 Exit Error (User) Closing-Exit Error-User #
458 User on Premises Opening-User on Prem. – User #
459 Recent Close Trouble-Recent Close – User # (Restore not applicable)
461 Wrong Code Entry Access – Wrong Code entry (Restore not applicable)
462 Legal Code Entry Access-Legal Code entry – user # (Restore not applicable)
463 Re-arm after Alarm Status-Re Arm After Alarm-User # (restore not applicable)