10 CA 251 O251-1EN1
MAN
O
AUTO
FREQ
METER
INSTRUMENTS AND CONTROLS, FUNCTIONAL DESCRIPTION
Items Designation Symbol Function
in fig.4
The left mode gives low amplitude.
Vibration is OFF in the O mode.
The right mode gives high amplitude.
Controls the flow of water to the tyres.
Continuous – Intermittent
Controls the flow of water to the drum.
MAN mode gives continuous watering.
Watering is OFF in the O mode.
The AUT mode gives automatic switching of
watering ON/OFF while driving forward or
reverse.
Switches on the vibration/frequency meter.
Released/engaged by the centre button.
Pull out to increase engine revs.
Push in to reduce. Turn/screw the handle to
adjust. Anticlockwise = increase and
clockwise = reduce.
Contains fuses for the electrical system.
See under the heading “Electrical system” for
description of function for the different fuses.
Manuals for safety, operating and maintenance
that are not to be removed from the machine.
Regulates movement of the strike-off blade
Up/Down. Move the lever down to lower,
and up to raise the blade.
28 Amplitude selector
29 Watering (A)
30 Watering (A)
31 Vibration/Frequency meter
(optional equipment)
32 Revs control (Diesel)
33 Fuse box
34 Handbook compartment
35 Lever, strike-off blade
UP/Down
(optional equipment)