20 LH700 ILH700EN1
MAINTENANCE – SERVICE POINTS
Item in fig.1 Maintenance see page Comments
9 Change eccentric element oil 24
10, 11 Change hydraulic fluid and filter 24
Lap intake and exhaust valves See engine manual.
Replace piston rings See engine manual.
Every 1000 hours of operation
Item in fig.1 Maintenance see page Comments
8 Change engine oil 21
4 Clean / replace oil filter See engine manual.
2 Clean / replace air cleaner elements See engine manual.
Check fuel injection pump See engine manual.
Check fuel injection nozzle See engine manual.
Adjust valve head clearance for intake
and exhaust valves See engine manual.
Every 500 hours of operation / Once a year
Item in fig.1 Maintenance see page Comments
8 Change engine oil 21
2 Clean / replace air cleaner elements See engine manual.
Every 100 hours of operation
When removing the battery, always dis-
connect the negative cable first. When fitting
the battery, always connect the positive
cable first.
Dispose of the old battery in the approved
environmentally suitable manner – batteries
contain toxic lead.
Do not use a quick-charger when charging the
battery. This may shorten the life of the battery.
WARNING
CAUTION