16.2. CE Marking
The CE mark certifies that the products meet the essential requirements of the applicable
regulations in line with the declaration of conformity. The manufacturer can be consulted
for a declaration of conformity.
(*a) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature
at heater outlet.
(*b) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for
other heaters 50 °C return temperature (at heater inlet).
(*c) High-temperature regime means 60 °C return temperature at heater inlet and 80 °C feed temperature
at heater outlet.
(*d) Low temperature means for condensing boilers 30 °C, for low-temperature boilers 37 °C and for
other heaters 50 °C return temperature (at heater inlet).
(*e) For heat pump heaters and combined heaters, the rated heat output Prated is the same as the
standard load in heating mode Pdesignh. The rated heat output of a Psup auxiliary heating device is the
same as the auxiliary heating power sup(Tj).
(*f) valid for HM models.
16.3. Product Information Sheet (ErP)
The product data presented below complies with the requirements of EU regulations 811/2013 and
813/2013 to supplement directives 92/42/EU and 92/42/EEC.
CE PIN Number: 0085CT0347
Product Data Symbol Unit
Cius Premix 14 Cius Premix 20 Cius Premix 24 Cius Premix 28
HM-HCH-HST HM-HCH-HST HM-HCH-HST HM-HCH-HST
Condensing appliance Yes Yes Yes Yes
Low-temperature boiler(*b) No No No No
B1 boiler No No No No
Cogeneraon Space Heater No No No No
Combinaon Heater Yes (for HM models) / No (for HCH and HST models)
Useful Heat Output
Rated heat output (*e) Prated kW 14 20 24 28
At rated heat output and high temperature regime (*a) P4 kW 14,1 20,2 24,5 28
At 30% of rated heat output and low temperature regime P1 kW 6,7 6,7 8,1 9,2
Auxiliary Electricity Consumpon
At full load elmax kW 0,025 0,034 0,044 0,051
At part load elmin kW 0,016 0,016 0,016 0,016
In Standby mode PSB kW 0,002 0,002 0,003 0,003
Space Heang Efficiency
Seasonal space heang energy efficiency class A A A A
Seasonal space heang energy efficiency ηs % 92 92 92 92
At rated heat output and high temperature regime (*c) η4 % 87,9 87,9 87,9 87,9
At 30% of rated heat output and low temperature regime (*d) η1 % 97 97 97 97
For Combinaon Heaters (*f)
Temperature applicaon (*f) Medium Medium Medium Medium
Declared load profile (*f) XL XL XL XL
Water heang energy efficiency class (*f) A A A A
Water heang energy efficiency (*f) ηwh % 85 85 85 84
Daily fuel consumpon (*f) Qfuel kWh 22,4 22,4 22,4 22,4
Annual fuel consumpon (*f) AFC Gj 18 18 18 18
Other Items
Standby Heat Loss Pstby kW 0,065 0,065 0,065 0,065
Ignion Burner Power Consumpon Pign kW 0 0 0 0
Annual Energy Consumpon QHE kWh 12267 17574 21315 24360
Daily Electricity Consumpon Qelec kWh 0,2 0,2 0,2 0,2
Annual Electricity Consumpon AEC average kWh 44 44 44 44
Sound Power Level L
wA
db(A) 46 46 46 52
Emission of Nitrogen Oxide NOx mg/kWh 36 40 44 48
Indicaon about ability working only during off-peak hours No No No No
Manufacturer
Emas Makina Sanayi A.Ş.
Address of the Manufacturer
Mustafa Kemal Bulvarı Organize Sanayi Bölgesi 3.Kısım No: 13 45030 MANİSA
Table 6.1. Versiyon A