e-survey ET2A User Manual

Default Icon
54 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
85°24’58’
280°13’58’
VA
HA
R
22-01-11 13:33
CRN REP
SFT
HOLD
ET2A
Electronic Digital Theodolite
USER GUIDE

Other manuals for e-survey ET2A

Question and Answer IconNeed help?

Do you have a question about the e-survey ET2A and is the answer not in the manual?

e-survey ET2A Specifications

General IconGeneral
Brande-survey
ModelET2A
CategoryIndustrial Equipment
LanguageEnglish

Summary

Before You Start

Precautions for Safe Operation

General safety precautions to minimize risk of personal injury and/or damage to property.

Caution

Specific warnings to avoid hazardous situations and potential damage to the instrument.

Warning

Critical warnings for qualified users to prevent eye damage, fire, electric shock, or explosion.

Danger

Critical dangers related to unauthorized disassembly and part replacement.

Disclaimer

Statement regarding user responsibility and limitations of manufacturer liability.

ET2A at a Glance

Quick Start

Insert / Replace the Battery

Procedures for inserting, replacing, and charging the instrument's battery.

Set up the Instrument

Steps for properly setting up the instrument on a marked ground point using the laser plummet.

Level the Circular Level

Method for leveling the circular bubble using foot screws for basic instrument leveling.

Level the Plate Level

Precise leveling technique using foot screws and the plate level.

Collimate the Target

Steps to align the instrument's optical sight and reticle with the target for accurate measurements.

Power on the Instrument

Instructions for powering on the ET2A theodolite, ensuring battery readiness.

Start Measurement

Guidance on initiating measurement procedures after the instrument is set up and powered on.

Angle Measurement

Measure a Horizontal Angle

Step-by-step process to measure a horizontal angle between two targets.

Hold the Horizontal Angle

Method to lock and hold a specific horizontal angle reading on the instrument.

Show the Vertical Angle in Percentage

Procedure to display the vertical angle measurement in percentage format.

Measure the Horizontal Angle Several Times

Technique to improve accuracy by measuring the same horizontal angle multiple times.

Measure the Zenith

Instructions for measuring the zenith angle using a diagonal eyepiece.

Distance Measurement

Laser Measurement

Measure the Orientation

Steps to find other points on a line using the laser for orientation.

Design the Target Angle

Procedure to establish a fiducial line using a designed horizontal angle with the laser.

Set the Level Line

How to use the red laser line as a level line for instrument setup.

Configuration Menu

Switch on/off the Tilt Compensator of the Vertical Angle

How to enable or disable the vertical angle tilt compensator.

Define the Zenith

Process to set the zenith reference point to 0° or 90°.

Set Automatic Power-off

Configuration to automatically turn off the instrument to save power.

Set the Minimum Angle Reading

Options to select the display format for the minimum angle reading.

Set the Baud Rate

Setting the communication speed (baud rate) for data transfer.

Set the Recording Medium

Choosing between serial port or instrument memory for data recording.

Set the Beep

Enabling or disabling the acoustic beep signal for specific angles.

Set the Angle Unit

Changing the unit of measurement for angles (degrees or gon).

Set the Date and Time

Procedures for setting the instrument's current date and time.

Check and Adjustment

Check and Adjust the Plate Level

Steps to check and adjust the plate level for precise instrument leveling.

Check and Adjust the Circular Level

Procedure to check and adjust the circular bubble for accurate leveling.

Check and Adjust the Vertical Line of the Reticle

Method to ensure the reticle's vertical line is perpendicular to the telescope's horizontal axis.

Check and Adjust the Line-of-Sight Error or Collimation Error

Process to determine and correct errors in the line of sight or collimation.

Check and Adjust the Vertical Index Error

Steps to check and adjust the vertical index error for accurate vertical angle readings.

Check and Adjust the Coinciding of the Laser Spot and Target Center

Procedure to align the laser spot with the target center using adjustment screws.