- To DISARM the system : Press the button once.
To disarm your system within proper operating range, simply press button once (while
system in arm position). The system will respond two siren chirp, two light flash, doors
unlock, Enable your engine starter, LED off.
- Disarm without siren chirp :Press the button over 2sec.
To disarm your system without siren chirp , simply press and hold the button for over
2sec. until the remote give 1 beep sound, then release the button . The system will
disarmed and without one siren chirp.
Note: this features is only activated under the system is in armed position.
- 2 step disarm:
This system offers 2 step disarm. It's a feature that make it possible to silence and reset
the system while it is triggering, without disarming the system. If the system is triggered
and the siren has been sounding, pressing any button once on the remote transmitter will
stop the trigger and return the unit to the armed state.
Note: Under system triggering, if press any button of 2-way remote once , the remote will
stop the beep sound and LCD display will indicate the intrusion icon for 2sec.
Press any button again to stop alarm triggering.
- 2nd step release start killer (Table-1 of NO.7 ON status):
If programmed with this feature, when disarming the system by the remote, however the
engine will still blocked, the status LED will fast flashing 4 times after a pulse and the 2way
LCD will turn on the icon for indication.
To exit : Turn ignition ON then (1) press Valet (over-ride) switch once . (2) or press remote
button once to release the start killer . The status LED will off to indicate the engine
released .
2-way LCD display :
+ Two beep sound
- Alarm cycle :
If a violation occurs the system will respond by sounding the siren and flashing the lights for
approximately 30sec. before the system resets itself and continues to protect your car. If
violation still occurs the system, siren and lights will working for 4 or 5 cycles then the
system reset itself and continues to protect other zones.
- Zone-1 / Zone-2 : 2nd stage sensor triggering limited for 4 cycles
- Door / Hood / Trunk zone triggering limited for 5 cycles