EDR-5000 IM02602007E
Name Description
AR.failed Signal: Auto Reclosing Failure
AR.Lock Signal: Auto Reclosure is locked out
AR.Pre Shot Pre Shot Control
AR.Ready Signal: Ready to shoot
AR.Running Signal: Auto Reclosing Running
AR.Standby Signal: Standby
AR.successful Signal: Auto Reclosing successful
Sync.In-Sync Allowed Signal: In-Sync Allowed
Sync.Sys-in-Sync Signal: Bus and line voltages are in synchronism according to the system synchronism criteria.
Sync.LiveBus Signal: Live-Bus flag: 1=Live-Bus, 0=Voltage is below the LiveBus threshold
Sync.LiveLine Signal: Live Line flag: 1=Live-Line, 0=Voltage is below the LiveLine threshold
Sync.SlipTooHigh Signal: Frequency difference (slip frequency) between bus and line voltages too high.
Sync.SynchronFailed Signal: This signal indicates a failed synchronization. It is set for 5s when the breaker is still open after the
Synchron-Run-timer has timed out.
Sync.SynchronRunTiming Signal: SynchronRunTiming
Sync.SyncOverridden Signal:Synchronism Check is overridden because one of the Synchronism overriding conditions (DB/DL or
ExtBypass) is met.
Sync.VDiffTooHigh Signal: Voltage difference between bus and line too high.
SysA.Alm Current Demd Signal: Alarm Current demand value
SysA.Alarm I THD Signal: Alarm Total Harmonic Distortion Current
SysA.Alarm V THD Signal: Alarm Total Harmonic Distortion Voltage
SysA.Alarm VA Demand Signal: Alarm VAs demand value
SysA.Alarm VA Power Signal: Alarm VAs peak
SysA.Alarm VAr Demand Signal: Alarm VARs demand value
SysA.Alarm VAr Power Signal: Alarm VArs peak
SysA.Alarm Watt Demand Signal: Alarm WATTS demand value
SysA.Alarm Watt Power Signal: Alarm WATTS peak
SysA.Trip Current Demand Signal: Trip Current demand value
SysA.Trip I THD Signal: Trip Total Harmonic Distortion Current
SysA.Trip V THD Signal: Trip Total Harmonic Distortion Voltage
SysA.Trip VA Demand Signal: Trip VAs demand value
SysA.Trip VA Power Signal: Trip VAs peak
SysA.Trip VAr Demand Signal: Trip VARs demand value
SysA.Trip VAr Power Signal: Trip VArs peak
SysA.Trip Watt Demand Signal: Trip WATTS demand value
SysA.Trip Watt Power Signal: Trip WATTS peak
Wired Inputs.52a M1-I State of the module input: Main 1 Breaker Closed
Wired Inputs.52b M1-I State of the module input: Main 1 Breaker Open