MAGNUM PRODUCT GUIDE CA013002EN—April 2017 www.eaton.com 43
Magnum trip units and communication devices
Digitrip trip units – Features
Digitrip 520
The Digitrip 520 trip unit is
designed to provide basic
overcurrent protection with
maximum economy. It is a
versatile trip unit with features
designed to provide flexibility
in overcurrent protection and
coordination. The Model 520 is
available on all Magnum circuit
breakers. Model features
include the following:
LI, LSI and LSIG Protection
Options with adjustable
Instantaneous Off Setting
Adjustable Long Delay Pick-
up Setting
Adjustable Long Delay Time
Setting
Long Time (Thermal)
Memory Trip
Over temperature Trip when
temperature exceeds 85°C
Adjustable Short Delay Pick-
up Setting
Adjustable Short Delay Time
Setting
Adjustable Instantaneous
Pick-up Settings
Adjustable Ground Pick-up
Setting
Adjustable Ground Time
Setting (limited to 1200A for
UL rated device)
Zone Interlocking of Short
Time and Ground Fault Time
Delay Functions
Test Port with Cover to
receive Hand Held Tester
Battery Included to Power
cause-of-trip LEDs after a
trip
Click here or search for
70C1037’ on www.eaton.
com, for more detailed
information on Magnum
Digitrip 520, 520M, and
520MC trip unit
Digitrip 520
Digitrip 520M
Digitrip 520M
Digitrip 520M includes all the
features of the Digitrip 520
while adding phase, neutral,
and ground fault (earth fault)
current metering with a four-
character LCD display window.
The additional features are as
follows:
LSI, LSIG and LSIA
Protection Options with
adjustable Instantaneous Off
Setting
4 Digit LCD Display
Step Pushbutton to Scroll
through LCD Display Data:
PH1 Phase 1 (A) Current
PH2 Phase 2 (B) Current
PH3 Phase 3 (C) Current
PH4 Neutral Current
PH5 Ground Current
HI Highest Phase Current
OL Overload Condition
HELP Trip Unit Error
Magnitude of Trip Current
Optional Ground (Earth)
Fault Alarm/Power Supply
Module: (Powers 4 digit
LCD display using customer
voltage source of 24-48 Vdc,
110 Vac, or 220 Vac)
Provides ground fault
alarm contact (when used
with LSIA)
Provides ground fault trip
contact (when used with
LSIG)
Provides a High Load
Alarm contact (when used
with LSI)
Alarm Contact rating (with
resistive load): (0.5 Amp
at 220 Vac ,
1.0 Amp at
110 Vac , or 1.0 Amp at
24-48 Vdc
High Load Red LED
Indicator (LSI Trip Units)
Provides power to keep
the 4-digit LCD display
functional when breaker is
open or lightly loaded.
ote:N If a ground alarm/power
supply module is not provided, the
4 Digit LCD Display will power up
when the 3-phase currents reach
approximately 20% of the sensor
rating or 30% of a single phase
current.
Click here or search for
70C1037’ on www.eaton.
com, for more detailed
information on Magnum
Digitrip 520, 520M, and
520MC trip units