4 Operational
4.5 Handling the keypad
130 DC1…20… and DC1…OE1 Variable Frequency Drives 02/20 MN040059EN www.eaton.com
4.5.2 Parameter structure
Table 23: Parameter groups
Parameter P-14 is used to control access to all parameter groups:
P-14 = P-37 (default setting: 101): enables access to the extended
parameter set (up to P-55 and up to P00-20)
P-14 = P-37 + 100 (default setting: 201): enables access to the extended
parameter set for version 1 (up to P-68 and up to P00-50)
Parameter group Value Range Part no. Access
rights
Display values P00-01 - P00-20 DC1-… ro
P00-21 - P00-50 DC1-…E1 ro
Basis parameters P-01 – P-14 DC1-… rw
Expansion P-15 – P-55 DC1-… rw
Expansion, version 1 P-60 – P-68 DC1-…E1 rw