EasyManua.ls Logo

Eaton PowerXL DC1 20 Series - Page 154

Eaton PowerXL DC1 20 Series
197 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 Technical Data
6.2 Specific rated operational data
150 DC1…20… and DC1…OE1 Variable Frequency Drives 02/20 MN040059EN www.eaton.com
6.2.1 DC1-1D…device series
Variable frequency drives with voltage doubler
U
LN
= 2 x U
2
: 115 V 230 V
Size Symbol Unit 2D3 4D3 5D8
Rated operational current I
e
A 2.3 4.3 5.8
Overload current for 60 s every 600 s i
l
A 3.45 6.45 8.7
Overload current for 2.5 s every 600 s i
l
A 4.03 7.53 10.15
Apparent power at rated operation
1)
230 V S kVA 0.92 1.71 2.31
Assigned motor power
at 230 V, 50 Hz P kW 0.37 0.75 1.1
at 220 - 240 V, 60 Hz P HP 0.5 1 1.5
Power side (primary side):
Number of phases single-phase or two-phase
Rated operating voltage U
LN
V 110 (-10 %) - 115 (+10 %) 48 - 62 Hz
99 - 126 ±0 %
Input current (phase current) I
LN
A 7.8 15.8 21.9
Minimum braking resistance R
B
Ω 100
Switching frequency (pulse frequency)
Default Setting f
PWM
kHz 8 8 8
Setting range f
PWM
kHz 4 - 32 4 - 32 4 - 32
Voltage Boost (U
Boost
/U
LN
)
Default Setting % 3 3 2.5
Max Value % 25 25 20
Maximum leakage current to earth (touch
current), at U
LN
: 120 V, without motor
I
Touch
mA 4.8 4.8 4.8
Efficiency η
0.95 0.95 0.95
Heat dissipation
At I
e
(150 %) P
V
W 18.5 37.5 44
During no-load running, standby
(locked, without fan)
P
V
W 3.07 3.07 4.51
Fan
1)
1)
Size FS1 FS1 FS2
1) Not with IP66 degree of protection

Table of Contents

Related product manuals