6 Technical Data
6.2 Specific rated operational data
154 DC1…20… and DC1…OE1 Variable Frequency Drives 02/20 MN040059EN www.eaton.com
6.2.4 DC1-34…device series
Size Symbol Unit 2D2 4D1NN
4D1FN
4D1NB
4D1FB
5D8 9D5
Rated operational current I
e
A 2.2 4.1 4.1 5.8 9.5
Overload current for 60 s every 600 s i
l
A 3.3 6.15 6.15 8.7 14.25
Overload current for 3.75 s every 600 s i
l
A 3.85 7.18 7.18 10.15 16.63
Apparent power at rated operation
400 V
SkVA1.52 2.84 2.84 4.02 6.58
Apparent power at rated operation
480 V
SkVA
1.83 3.41 3.41 4.82 7.9
Assigned motor power
at 400 V, 50 Hz P kW 0.75 1.5 1.5 2.2 4
at 460 V, 60 Hz P HP
1 2 2 3 5
Power side (primary side):
Number of phases 3 3 3 3 3
Rated operating voltage U
LN
V 380 V - 10 % - 480 V + 10 %, 50/60 Hz
342 - 528 V ±0 %, 48 - 62 Hz ±0 %
Input current (phase current) I
LN
A 3.5 5.6 5.6 7.5 11.5
Minimum braking resistance R
B
Ω 250 200 120
Switching frequency (pulse frequency)
Default Setting f
PWM
kHz 8 8 8 8 8
Setting range f
PWM
kHz 4 - 32 4 - 32 4 - 32 4 - 32 4 - 32
Voltage Boost (U
Boost
/U
LN
)
Default Setting % 3 3 2.5 2.5 2.5
Max Value % 25 25 20 20 20
Maximum leakage current to earth
(touch current), at U
LN
: 400 V, without
motor
I
Touch
mA 13 13 12.6 12.6 12.6
Efficiency η
0.92 0.95 0.95 0.95 0.97
Heat dissipation
At I
e
(150 %) P
V
W 33.75 66.5 66.5 101.2 136
During no-load running, standby
(locked, without fan)
P
V
W 4.55 4.55 6.44 6.44 6.44
Fan
1)
1)
1)
1)
1)
Size FS1 FS1 FS2 FS2 FS2
1) Not with IP66 degree of protection