EasyManuals Logo

Eaton VICKERS SystemStak User Manual

Eaton VICKERS SystemStak
55 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
Performance Characteristics
Pressure Drop
Typical performance with mineral oil at 21 cSt (102 SUS) and at 50_C(122_F)
Type 1 needle (see model codes and )
Type 2 needle (see model codes and )
Free flow through check valve
3 6 3 6
0
bar
50 6040302010 L/min
0 4 8 12 16 USgpm
0
psi
Flow rate
30
200
400
Pressure drop
Number of turns of adjuster
123 4 5 6
10
20
40
50
60
600
800
0
bar
50 6040302010 L/min
0 4 8 12 16 USgpm
0
psi
Flow rate
30
200
400
Pressure drop
Number of turns of adjuster
12 3 4
5
6
10
20
40
50
60
600
800
0
bar
50 6040302010 L/min
0 4 8 12 16 USgpm
0
psi
Flow rate
200
Pressure drop
150
100
50
14
2
4
6
8
10
12
For other viscosities see Further Information.
20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eaton VICKERS SystemStak and is the answer not in the manual?

Eaton VICKERS SystemStak Specifications

General IconGeneral
BrandEaton
ModelVICKERS SystemStak
CategoryControl Unit
LanguageEnglish