EasyManuals Logo

Eaton VICKERS SystemStak User Manual

Eaton VICKERS SystemStak
55 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #7 background imageLoading...
Page #7 background image
Installation Dimensions in mm (inches)
DGMC(2)-3**-**(-B*-**)-4*
Models with type W adjuster
To adjust valve setting slacken off locknut
and turn adjuster screw .
Turn clockwise to increase pressure;
counter-clockwise to decrease pressure
Re-tighten locknut after completing
adjustment.
For gage port thread options see model code
A
P
B
T
A
P
B
T
A max.
79 (3.1)
fully out
Line B or line P adjustment
(according to model type)
Line A adjustment
B max.
4 (0.16) max. over gage port plug
4 (
5
/
32
) A/F hex. socket
40
(1.57)
3,5 (0.14)
Ø3 (0.12 dia)
20
(0.79)
47,6
(1.87)
46
(1.8)
39 (1.54)
76 (3)
C max.
D max.
4 off O seals supplied for this mounting face4 holes through: Ø5,3 (0.21 dia)
12,7 (
1
/
2
) A/F hex. locknut
Torque to 25-30 Nm (18-22 lbf ft)
8
Model A B C D
DGMC-3-AT-*W-4* ––154 (6.1)
DGMC-3-BT-*W-4* –––156 (6.2)
DGMC-3-AT-*W-*-4* 160 (6.3) ––
DGMC-3-PT-*W-4* –––156 (6.2)
DGMC-3-PT-*W-*-4* 160 (6.3) ––
DGMC2-3-AT-*W-BT-*W-4* 234 (9.2) –––
7

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eaton VICKERS SystemStak and is the answer not in the manual?

Eaton VICKERS SystemStak Specifications

General IconGeneral
BrandEaton
ModelVICKERS SystemStak
CategoryControl Unit
LanguageEnglish

Related product manuals