6 Operation
6.3 Switching off the device
46 MICRO PANEL XVS400 10.4"/12.1"/15" 10/2011 MN04802012Z-EN www.eaton.com
6.3 Switching off the device
1 De-energize the device.
CAUTION
Data loss
During a write operation, the CF card may lose data or may be destroyed if it is re-
moved or if there is a power failure.
Always secure CF cards with the CF slot cover.
Avoid write operations to CF cards. Reasons:
- The number of write cycles possible on CF cards is limited.
- A power failure during write operations will most likely lead to loss of data.
Before removing the CF card in CF slot 1, ensure that no software write opera-
tions to the CF card are in progress («CF ACT» LED must not be lit).
Only remove the CF card from CF slot 0 when the device is in a de-energized
state.
Before switching off, ensure that no software write operations to the CF card are
in progress («CF ACT» LED must not be lit).
Frequent on/off switching of the device, especially at low temperatures, will reduce the
lifespan of the cold cathode tubes (CCFL) of the backlight.
Avoid frequent on/off switching of the device.
Reduce the brightness of the backlight instead ( Document «MN05010007Z-EN
System Description Windows CE»).