EasyManua.ls Logo

EBS LX20B - Page 29

EBS LX20B
67 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
LX20B Manual Page 29 / 67
Server IP address
It is address of receiver of monitoring system (OSM.Server) or computer where
“Communication Server” software has been installed , e.g. 89.123.115.8. This
address may be provided in domain name of server, e.g. modul.gprs.com.
Server phone number
If GSM modem is connected to server application (e.g. OSM.Server) enter in this
field its number. Any SMS will be sent to this number if transmitter has got
problems with GPRS transmission.
If this field is left blank or 0 was entered, the transmitter will be operating
exclusively in GPRS mode.
Note: This field will be inactive if device is to operate in GPRS mode.
APN Scheme
After entering the data in the boxes below, you can save the scheme with the
parameters by pressing "+" next to the APN field. In order to delete the scheme,
press "-".
APN
Parameter depending on GSM network operator that supplies GPRS (SMS) services.
It provides GSM network access point name.
It possible to obtain a private access point. In this case a name will be provided by
GSM network operator.
User ID
When using public APN, user ID is mostly not required. For private APN this
parameter shall be obtained from operator (it is impossible to be granted access to
GPRS network without it).
User password
When using public APN, user ID is mostly not required. For private APN this
parameter shall be obtained from operator (it is impossible to be granted access to
GPRS network without it).
Note: Private APN provides for higher system security.
7.1.2.2.2. Secondary server
This section concerns the backup server and the SIM card 2. Fields should be
completed with data by analogy with the primary server.

Table of Contents

Related product manuals