7.3.2. Partitions
Partitions are configured using Partitions tab.
7.3.2.1. Partition arming input
Using this option, partition arming input can be selected. To selected input, arming
device (e.g. switch, remote controller receiver or coded lock) can be connected.
When this input is violated (armed), the partition is armed (after Exit Time). When
arming input is not violated (disarmed), partition is disarmed.
7.3.2.2. Inputs assigned to partitions
Assigning input to partition means that it is monitored only when partition to which
input belongs is armed. Input can be assigned up to one partition. Arming inputs
can not be assigned to any partition. If input is not assigned to any partition, it acts
as 24 hours input it is monitored regardless of partitions state.
7.3.2.3. Delayed inputs
Here, delayed inputs can be selected. Delayed input switches on associated output,
ie. generates alarm, after expiry of Entry time, but only when partition to which
input belongs will not be disarmed before Entry time period.