o EVENT_CONFIGURATION_CHANGED
o EVENT_SERVICE_BEGIN
o EVENT_SERVICE_END
o EVENT_INCOMING_DATACALL_BEGIN
o EVENT_INCOMING_DATACALL_END
o EVENT_FIRMWARE_CHANGED.
o To OSM Server is sent information abort the occurrence of the event and the
number of occurrences without giving a time (eg. A violation of input 2: 14
times).
o Events may be sent not in chronological order, even though the transmiter is
trying to send earlier, the events which occurred first.
o Command FLUSH=0, deletes only the events stored in the volatile memory
and generates the event EVENT_FIFO_FLUSHED.
Regardless of choosing the option “Enable non-volatile events FIFO”:
o If in the memory are unsent messages from the control panel and the
memory will be disabled by changing the configuration, unsent events can be
sent when the memory will be enabled again.
Memory related events:
o EVENT_FIFO_FAILURE – when queue is damaged.
o EVENT_FIFO_OVERFLOW – when queue is overflowed.
o EVENT_FIFO_FLUSHED – when queue is cleared by remote command
FLUSH=0.
7.4.2. GPRS On / GPRS Off
In this column you define signals that are to be reported to monitoring station with
GPRS transmission. There is possibility to send information on alarms (input state
change from rest to action status) and on returns of input state from action to rest
(normalization).
To transmit any signal you should only click it (proper square on your right).
Click on [Clear] button to remove all marked signals.
Click on [Invert] button to change markings to contrary.