LX2NB Manual v.1.9 Page 31 / 60
7.3.2. Partitions
Partitions are configured using 3.Inputs/Outputs->Partitions tab.
7.3.2.1. Partition arming input
Using this, partition arming input can be selected. To selected input, arming device
(remote controller receiver output or electronic keyboard NO/NC output for
instance) is connected. When this input is armed, partition is armed (after Exit
Time, see below). When arming input is disarmed, partition is disarmed.
7.3.2.2. Inputs assigned to partitions
Assigning input to partition means that it is monitored only when partition to which
input belongs is armed. Input can be assigned up to one partition. Arming inputs
can not be assigned to any partition. If input is not assigned to any partition, it acts
as 24 hours input – it is monitored regardless of partitions state.