EasyManua.ls Logo

Eccotemp SHLX - Installation Checklist

Eccotemp SHLX
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PLEASE NOTE: SH12
-
A IS FOR INDOOR PERMANENT INSTALLATIONS ONLY. THIS MANUAL AND ALL ECCOTEMP CONTENT IS SUBJECTED TO CHANGE WITHOUT NOTICE.
PLEASE VISIT SUPPORT.ECCOTEMP.COM FOR MORE INFORMATION.
28
28
Support: Support.Eccotemp.com Shop Online: www.Eccotemp.com Phone: 866-356-1992
English
Installation
INSTALLATION CHECKLIST
Water Heater Location
Installed INDOORS.
Close to area of mostly used outlet.
Protected from freezing temperatures.
Proper clearance from combustible surfaces observed.
Sucient fresh air supply for proper operation of water heater.
Air supply free of corrosive elements and ammable vapors.
Provisions made to protect area from water damage.
Sucient room to service heater.
Combustible materials, such as clothing, cleaning materials, rags, etc., clear of the water heater and vent
piping.
Water heater is properly attached to the wall.
Ensure a backow system has been installed to the vent piping.
Install a condensation trap and drain (as required).
Water Supply
Water supply has sucient pressure and 1/2” NPT water lines.
Air purged from water heater and piping.
Water connections tight and free of leaks.
Water lter is clean and in place.
Materials used are as instructed in this manual.
Water pipes are insulated.
Gas Supply
Gas type matches rating plate.
Gas supply pressure is sucient for the water heater.
Gas line equipped with shut-o valve, union and sediment trap.
Approved pipe joint compound used.
Commercial leak detector or soap and water solution used to check all connections and ttings for
possible gas leaks.
Gas company inspected installation (if required).
It is recommended that the minimum BTUs in the ex and gas lines be 1” black steel, ex rated at a
minimum of 150,000 BTUs.
Relief Valve
Pressure relief valve properly installed and discharge line run to open drain.
Discharge line protected from freezing.
Electrical Wiring
Voltage matches rating plate.
Water heater is properly grounded.
Wiring meets all local codes.
GFCI Protection where required.

Related product manuals