Installation
INSTALLATION CHECKLIST
Water Heater Location
Installed INDOORS.
Close to area of mostly used outlet.
Protected from freezing temperatures.
Proper clearance from combustible surfaces observed.
Sucient fresh air supply for proper operation of water heater.
Air supply free of corrosive elements and ammable vapors.
Provisions made to protect area from water damage.
Sucient room to service heater.
Combustible materials, such as clothing, cleaning materials, rags, etc., clear of the water heater and vent
piping.
Water heater is properly attached to the wall.
Ensure a backow system has been installed to the vent piping.
Install a condensation trap and drain (as required).
Water Supply
Water supply has sucient pressure and 1/2” NPT water lines.
Air purged from water heater and piping.
Water connections tight and free of leaks.
Water lter is clean and in place.
Materials used are as instructed in this manual.
Water pipes are insulated.
Gas Supply
Gas type matches rating plate.
Gas supply pressure is sucient for the water heater.
Gas line equipped with shut-o valve, union and sediment trap.
Approved pipe joint compound used.
Commercial leak detector or soap and water solution used to check all connections and ttings for
possible gas leaks.
Gas company inspected installation (if required).
It is recommended that the minimum BTUs in the ex and gas lines be 1” black steel, ex rated at a
minimum of 150,000 BTUs.
Relief Valve
Pressure relief valve properly installed and discharge line run to open drain.
Discharge line protected from freezing.
Electrical Wiring
Voltage matches rating plate.
Water heater is properly grounded.
Wiring meets all local codes.
GFCI Protection where required.