(11) Set the Barfield Pitot/Static Tester DPS450 static pressure to 40,613 feet and set the
airspeed to 159.2 knots as follows:
(a)
Press ALT Ps to select the ALT control aim, enter 40613 and press ENTER.
Press SPEED Qc, enter 159.2 and press ENTER. Wait for at least a 15 second
stabilization period after the altitude and airspeed achieve these new air data
parameter set point values to continue.
(12) Record the left PFD altimeter and airspeed.
Expected results are 41,000 ± 40 feet, 160 ± 2.5 knots, and 0.575 ± 0.008 Mach.
(13) Set the Barfield Pitot/Static Tester DPS450 static pressure to 29,698 feet and
increase the airspeed to 199.3 knots as follows:
(a) Press ALT Ps to select the ALT control aim, enter 29698 and press Enter. Press
SPEED Qc, enter 199.3 and press ENTER. Wait for at least a 15 second
stabilization period after the altitude and airspeed achieve these new air data
parameter set point values to continue.
(14) Record the left PFD altitude and airspeed.
Expected results are 30,000 ± 40 feet, 200 ± 2.7 knots and 0.557 ± 0.006 Mach.
(15) Set the Barfield Pitot/Static Tester DPS450 static pressure to 19,706 feet and
increase the airspeed to 237.6 knots as follows:
(a) Press ALT Ps to select the ALT control aim, enter 19706 and press Enter. Press
SPEED Qc, enter 237.6 and press ENTER. Wait for at least a 15 second
stabilization period after the altitude and airspeed achieve these new air data
parameter set point values to continue.
(16) Record the left PFD altitude and airspeed.
Expected results are 20,000± 40 feet, 240 ± 3 knots and 0.535 ± 0.006 Mach.
(17) Set the Barfield Pitot/Static Tester DPS450 static pressure to 9,872 feet set the
airspeed to 195.9 knots as follows:
(a) Press ALT Ps to select the ALT control aim, enter 9872” and press Enter. Press
SPEED Qc, enter 195.9 and press Enter. Wait for at least a 15 second
stabilization period after the altitude and airspeed achieve these new air data
parameter set point values to continue.
(18) Record the left PFD altitude and airspeed.
Expected results are 10,000± 33 feet and 200 ± 2.7 knots.
(19) Set the Barfield Pitot/Static Tester DPS450 static pressure to 6,008 feet and set the
airspeed to 66.1 knots as follows:
(a) Press ALT Ps to select the ALT control aim, enter 6008 and press Enter. Press
SPEED Qc, enter 66.1 and press Enter. Wait for at least a 15 second
stabilization period after the altitude and airspeed achieve these new air data
parameter set point values to continue.
(20) Record the left PFD altimeter and airspeed.
Expected results are 6,000 ± 25 feet and 65 ± 2 knots.
(21) Press GROUND to go to atmospheric pressure. Press F1 to select Yes to confirm.
EA500 Aircraft Maintenance Manual — 06-117751