(9) Set both the left and right PFD Baro to 29.92 by using the BARO SET knob on the
ACP.
Make sure the baro setting matches on the left and right PFD.
(10)
Power on the Barfield Pitot/Static Tester DPS500 by selecting OPERATE and PUMP
switches to ON. Wait for the Barfield Pitot/Static Tester DPS500 to Confirm Settings.
After a successful self-test sequence, the system changes to the Warm Up
mode.
(11) Set the Barfield Pitot/Static Tester DPS500 static pressure to 40,613 feet and set the
airspeed to 159.2 knots as follows:
(a) Press ALT Ps to select the ALT control aim, enter 40613 and press Enter. Press
SPEED Qc, enter 159.2 and press ENTER. Wait for at least a 15 second
stabilization period after the altitude and airspeed achieve these new air data
parameter set point values to continue.
(12) Record the left PFD altitude and airspeed.
Expected results are 41,000 ± 40 feet, 160 ± 2.5 knots and 0.575 ± 0.008 Mach.
(13) Set the Barfield Pitot/Static Tester DPS500 static pressure to 29,698 feet and
increase airspeed to 199.3 knots as follows:
(a) Press ALT Ps to select the ALT control aim, enter 29698 and press Enter. Press
SPEED Qc, enter 199.3 and press Enter. Wait for at least a 15 second
stabilization period after the altitude and airspeed achieve these new air data
parameter set point values to continue.
(14) Record the left PFD altitude and airspeed.
Expected results are 30,000 ± 40 feet, 200 ± 2.7 knots, and 0.557 ± 0.006 Mach.
(15) Set the Barfield Pitot/Static Tester DPS500 static pressure to 19,706 feet and
increase airspeed to 237.6 knots as follows:
(a) Press ALT Ps to select the ALT control aim, enter 19706 and press Enter. Press
SPEED Qc, enter 237.6 and press Enter. Wait for at least a 15 second
stabilization period after the altitude and airspeed achieve these new air data
parameter set point values to continue.
(16) Record the left PFD altitude and airspeed.
Expected results are 20,000± 40 feet, 240 ± 3 knots, and 0.535 ± 0.006 Mach.
(17) Set the Barfield Pitot/Static Tester DPS500 static pressure to 9,872 feet and set
airspeed to 195.9 knots as follows:
(a) Press ALT Ps to select the ALT control aim, enter 9872 and press Enter. Press
SPEED Qc, enter 195.9 and press Enter. Wait for at least a 15 second
stabilization period after the altitude and airspeed achieve these new air data
parameter set point values to continue.
(18) Record the left PFD altitude and airspeed.
Expected results are 10,000± 33 feet and 200 ± 2.7 knots.
(19) Set the Barfield Pitot/Static Tester DPS500 static pressure to 6,008 feet and set
airspeed to 66.1 knots as follows:
EA500 Aircraft Maintenance Manual — 06-117751
Temporary Revision No. 34-21
EFFECTIVITY: NOTED
34-10-00
Page 524
Sep 30/20
© 2020 Eclipse Aerospace, Inc.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Eclipse EA500 and is the answer not in the manual?

Eclipse EA500 Specifications

General IconGeneral
BrandEclipse
ModelEA500
CategoryAircrafts
LanguageEnglish

Related product manuals