9 Maintenance
Personnel:
n
Mechanic
n
Service personnel
CAUTION!
Maintenance may be performed only by authorized persons possessing the
necessary specialist knowledge and experience.
Interval Maintenance work
Quarterly Check/inspection Suction, pressure and return lines for leak-free connection.
Check/inspection Housing bolts for firm seating, tighten to 8 Nm torque if necessary.
Check/inspection Overflow function (overpressure).
Maintenance interval: Quarterly, shorter intervals in case of heavier loading
(e.g. continuous operation).
CAUTION!
The system must be depressurized and drained prior to any maintenance
or repair work which necessitates opening of the MFV!
Please adhere under all circumstances to the product data-sheet for the
metered fluid, in order to avoid injuries of all types!
Maintenance
32417101434 Rev. 5-05.2019