EasyManua.ls Logo

Ecolab Ecoplus EXN-II - User Manual

Ecolab Ecoplus EXN-II
204 pages
Go to English
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Betriebsanleitung
Operating Instructions
Manuel d'utilisation
Ecoplus EXN-II
Steuerung
Control unit
Unité de contrôle
DEUTSCH
ENGLISH
FRANÇAIS
MAN054003, Ecoplus EXN-II
Rev. 1-02.2024
29.02.2024

Table of Contents

Questions and Answers

  • M
    Mark LeeSep 9, 2025
    What causes error code 255 on Ecolab Control Unit and how to resolve it?
    • M
      mary76Sep 9, 2025
      If the Ecolab Control Unit displays error code 255, it indicates that the water change interval has been exceeded. To resolve this, you may need to empty and clean the commercial dishwasher, or adjust the parameters as required [display 50].
  • J
    Jill JenkinsAug 23, 2025
    What to do if Ecolab Ecoplus EXN-II displays error code 201?
    • M
      Mark CastanedaAug 23, 2025
      If your Ecolab Control Unit displays error code 201, several issues could be the cause. It might be due to an empty capsule, requiring you to insert a new one. Alternatively, the wrong product might be in use; in this case, you should rinse the unit and product lines with water and then use the correct chemical product. A defective measuring cell could also trigger this error, necessitating its replacement. Finally, the PCB itself might be defective, requiring a board change.
  • H
    Heather OchoaAug 25, 2025
    How to fix Ecolab Ecoplus EXN-II error code 202?
    • R
      Rhonda ThomasAug 25, 2025
      If the Ecolab Control Unit displays error code 202, it could be due to several reasons. First, check if a capsule is inserted; if not, insert one. If the capsule is present, the capsule switch might be defective, requiring you to check the switch and its wiring, and replace it if necessary. In some cases, the circuit board itself could be defective, necessitating a change of the circuit board.
  • C
    Christian WilliamsAug 26, 2025
    What causes error code 203 on Ecolab Ecoplus EXN-II Control Unit display?
    • M
      montgomerychristinaAug 26, 2025
      If your Ecolab Control Unit displays error code 203, the issue might stem from a few potential causes. First, check if the cover is open and close it. If the cover is closed, the ceiling electronics could be defective, requiring you to check the cover wiring and replace the cover if necessary. As a last resort, the circuit board itself might be defective, which would mean changing the circuit board.
  • S
    solomontimothyAug 27, 2025
    Why does Ecolab Ecoplus EXN-II Control Unit show error code 204?
    • M
      Matthew WallaceAug 27, 2025
      If the Ecolab Control Unit displays error code 204, it could indicate a few potential problems. The unit might be signaling an empty liquid cleaner, requiring you to change the cleaner. Alternatively, the suction lance might be defective, so you should check its function and replace it if needed. In some instances, the circuit board itself could be defective, necessitating a change of the circuit board.
  • N
    nbriggsSep 22, 2025
    Why is date/time not saved on Ecolab Ecoplus EXN-II?
    • K
      Kristy CampbellSep 22, 2025
      If the date/time is not being saved on your Ecolab Control Unit, it is likely due to a defective or empty CMOS battery. The suggested solution is to replace the WWC PCB.
  • J
    James OwensSep 16, 2025
    What is the reason for error code 0214 on Ecolab Ecoplus EXN-II display?
    • A
      Andrew SaundersSep 16, 2025
      If the Ecolab Control Unit displays error code 0214, which relates to Detergent SQP (cable breakage), where applicable, pump back-pressure may be too high. Check hydraulic lines and rinse if necessary. Also, check the connecting cable. If none of those are the issue, the motor may be defective, and you will need to change it.
  • R
    Ryan NewtonSep 18, 2025
    How to resolve error code 0215 on Ecolab Ecoplus EXN-II display?
    • D
      David PrinceSep 18, 2025
      If the Ecolab Control Unit displays error code 0215, related to Rinse aid SQP (short circuit), pump back-pressure may be too high. Check hydraulic lines and flush if necessary. Check the connection cable. If the issue persists, the motor might be faulty, and you should change it.
  • C
    chase16Sep 7, 2025
    How to fix error code 254 on Ecolab Ecoplus EXN-II?
    • D
      david17Sep 7, 2025
      If the Ecolab Control Unit displays error code 254, it may be due to a parameter limit value set too high. You may need to adjust parameters [display 64] Note: Where applicable, the choice of position of the sensor is unsuitable, the temperature display does not match the GGSM. Another possible cause is a defective temperature sensor, requiring you to check its function and replace it if necessary.
  • A
    Alice WilsonSep 4, 2025
    What does error code 252 mean on Ecolab Ecoplus EXN-II display?
    • J
      Jordan MahoneySep 4, 2025
      If the Ecolab Control Unit displays error code 252, it could indicate that a parameter limit value is set too high. You may need to adjust parameters [Display 47]. Note: Where applicable, the choice of position of the measuring cell is unsuitable, the temperature display does not match the GGSM. Another possible cause is a defective measuring cell, requiring you to check its function and replace it if necessary.

Summary

General Information

Notes on Operating Instructions

Guidelines for reading and understanding the operating instructions before use.

Accessing Operating Instructions

Methods for accessing manuals via website, DocuAPP for Windows, and mobile devices.

Manual Representation and Information

Explanation of symbols, article numbers, and manual conventions.

Transportation and Returns

Transportation and Returns Procedures

Guidelines for transporting, inspecting, and returning the unit.

Conditions for Returns and Packaging

Safety conditions for returns, online request process, and shipping guidelines.

Packaging and Storage

Packaging, Storage, and Equipment Marking

Instructions on packaging, storage conditions, and equipment identification.

Warranty and Contact Information

Warranty Conditions and Manufacturer Contact

Details on warranty, CE conformity, and contact information for manufacturer and support.

Safety

General Safety Advice and Intended Use

Essential safety guidelines, intended use, and foreseeable misuse of the unit.

Operator and Personnel Safety Measures

Safety measures, operator responsibilities, and personnel requirements.

Personnel Roles and Qualifications

Details on personnel requirements, qualifications, and responsibilities.

PPE and Hazard Warnings

Required Personal Protective Equipment (PPE) and warnings for auxiliary/unauthorised personnel.

General Hazards: Electrical Energy and Start-up

Information on electrical hazards, unauthorised access, and automatic start-up risks.

Safety for Installation, Maintenance, and Repair

Critical safety precautions for performing installation, maintenance, and repair work.

Delivery

Delivered Components Overview

List and brief description of items included in the delivery package.

Mounting Kit and Drilling Template

Details on the mounting kit and drilling template for installation.

Function Description and Design

Unit Functionality and Keypad Operations

Description of the Ecoplus EXN-II's function and how to operate its keypad.

Interfaces and USB Functionality

Overview of unit interfaces and the use of the USB port for data management.

Assembly and Connection

Safety Precautions for Assembly

Essential safety warnings and PPE requirements for assembly and connection.

Assembling the Ecoplus EXN-II Unit

Step-by-step guide for the physical assembly of the Ecoplus EXN-II.

Electrical Installation and Wiring Diagram

Detailed wiring diagram and instructions for electrical connections.

ESD Protection and Interference Prevention

Precautions against electrostatic discharge and electromagnetic interference.

Connecting Inputs and Outputs

Detailed steps for connecting unit inputs and outputs.

Setting the Buzzer Volume

Procedure for adjusting the alarm buzzer volume on the controller.

Start-up

Personnel and Software Information

Personnel required for start-up and notes on control PCB software instructions.

Pictograms and Program Structure

Explanation of pictograms and overview of the unit's program structure.

Program Navigation and Settings Overview

Guide to navigating the program structure and accessing main settings.

Initial Commissioning Procedure

Step-by-step guide for the initial commissioning (Erstinbetriebnahme) of the unit.

Setup Menu and Basic Configurations

Guide to the Setup menu for configuring dishwasher type, detergent, and rinse aid.

Operation

Switching the Unit On

Instructions on how to power on the Ecoplus EXN-II unit.

Temporarily Taking the Unit Out of Operation

Procedure for putting the unit into standby mode and resuming operation.

Booster Activation and Deactivation

Instructions for activating and manually disabling the booster function.

Entering the Access Code

Procedure for entering the access code to access unit functions.

Import;Export Functionality

Guide to importing and exporting configuration and operating data.

Malfunctions and Troubleshooting

General Troubleshooting and Fault Rectification

Table of common faults, their causes, and remedies.

Fault Messages and Error Codes

Explanation of fault codes and error messages displayed by the unit.

Specific Error Code Troubleshooting (201-203)

Troubleshooting steps for specific error codes related to products and covers.

Temperature Error Codes (251-252)

Troubleshooting for errors related to tank temperature being too low or too high.

Measuring Cell and Interference Errors (0210-0212)

Troubleshooting for measuring cell connection, temperature, and interference issues.

Internal Component and Alarm Errors

Troubleshooting for internal component errors and important alarm notes.

Maintenance

Safety Precautions for Maintenance Work

Essential safety instructions and warnings before performing maintenance.

Maintenance Tasks and Tool Usage

Guidelines on maintenance tasks, tool usage, and periodic maintenance schedules.

Cleaning and Functional Testing

Procedures for cleaning the unit's exterior and performing functional tests.

Spare Parts List; Accessories

Spare Parts

List of available spare parts with part numbers.

Accessories

List of optional accessories with part numbers.

Technical Data

General Technical Specifications

Details on supply voltage, power, dimensions, weight, and interfaces.

Measurement, Environmental, and Ambient Data

Technical data on measurement ranges, environmental load, and ambient conditions.

Decommissioning, Disassembly, Environmental Protection

Taking Unit Out of Operation and Dismantling Safety

Safety procedures for taking the unit out of operation and dismantling.

Dangers of Improper Removal and Tool Use

Warnings regarding injury risks from improper dismantling and incorrect tools.

Disposal and Environmental Protection Guidelines

Procedures for component disposal and environmental protection measures.

Appendix

Technical Documents: Representatives and Declarations

List of Ecolab representatives and the EC Declaration of Conformity.

Pump Configuration Overview

Overview of pump setting configuration for the Ecoplus EXN-II.

Setup Parameters: Dish Washer, Detergent, Rinse Aid

Details on configuring Dish Washer Type, Detergent, and Rinse Aid settings.

Setup Parameters: Product Selection and Dosing Mode

Details on configuring Product Selection and Dosing Mode.

Ecolab Ecoplus EXN-II Specifications

General IconGeneral
BrandEcolab
ModelEcoplus EXN-II
CategoryControl Unit
LanguageEnglish

Related product manuals