Fig. 24: Depiction of ‘Rinse Aid SQP Error’
No. Fault description Cause Remedy
215 Display:
Error code 0215
Rinse aid SQP (short
circuit)
Pump back-pressure may be too high: Check hydraulic lines, flush
if necessary
.
Check the connection cable.
Motor faulty, change.
216 Display:
Error code 0216
Rinse aid SQP (cable
break)
Pump back-pressure may be too high: Check hydraulic lines, flush
if necessary
.
Check the connection cable.
Motor faulty, change.
Fig. 25: Error code 1234
No. Fault description Cause Remedy
2xxx Display:
Error code 2xxx
EEPROM U2
n Check whether the EEPROM is correctly plugged into the 8-pin socket
n Where applicable, change PCB
3xxx Display:
Error code 3xxx
FRAM U3
Change PCB
4xxx Display:
Error code 4xxx
Flash U4
Change PCB
1001 Display:
Error code 1001
RTCC
Change PCB
Please note for alarms 250 to 299: Do NOT stop the dosing!