12 Decommissioning, disassembly, environmental protection
Personnel:
n
Specialist
Protective equipment:
n
Chemical-resistant protective gloves
n
Protective eyewear
n
Safety shoes
DANGER!
Risk of injury due to the disregard of the specified personal protective
equipment (PPE)!
For all disassembly work, please respect the use of the PSA which is specified
on the product data sheet.
12.1 Taking unit out of operation
DANGER!
The procedures described here may only be carried out by skilled personnel as
described at the start of the chapter
, this may only be done using PPE.
The procedure for decommissioning is as follows:
1. Shut of
f water supply if necessary (close angle valve).
2. Before carrying out any subsequent work, first isolate the electrical supply and
secure it against being switched on again.
3. Disconnect unit from mains (pull out mains plug) or turn the software to "OFF": Press
the left-hand and right-hand keys simultaneously for 5 seconds.
4. Physically disconnect the entire power supply; release stored residual energy
.
5. Drain and remove operating fluids and consumables.
6. Remove the remaining processing materials and dispose of them in an
environmentally friendly way
.
Decommissioning, disassembly, environmental protection
58MAN054003, Ver. 1-02.2024