Fig. 22: Illustration ‘measuring cell error’
No. Fault description Cause Remedy
210 Screen:
Error code 0210
No measuring cell connected
Connect measuring cell
Temperature < 0° C
Temperature must be > 0°C
Measuring cell defective,
(NTC sensor breakage)
Check measuring cell, change if necessary
Cable breakage
Check wiring, change if necessary
211 Screen:
Error code 021
1
Measuring cell defective,
(NTC short-circuit)
Check measuring cell, change if necessary
Temperature > 100°C
Temperature must be < 100°C
Cable short circuit
Check wiring, change if necessary
212 Screen:
Error code 0212
Measuring cell leaking,
(conductivity short-circuit)
Check measuring cell, change if necessary
Cable short circuit
Check wiring, change if necessary
Electromagnetic interference
Install the measuring cell and its cable away from
possible sources of electromagnetic interference:
n Lay the measuring cell cable as far away from
the dishwasher pump motor as possible.
n Do not lay measuring cell cables together with
high-voltage cables in a cable duct.
n Do not install the measuring cell and its cable
near frequency-controlled motors, mobile phone
antennas or WLAN antennas.
Fig. 23: Illustration ‘detergent SQP error’
No. Fault description Cause Remedy
213 Display:
Error code 0213
Detergent SQP (short-
circuit)
Where applicable, pump back-pressure too high: Check hydraulic
lines, where applicable rinse.
Check connecting cable.
Motor defective, change
214 Display:
Error code 0214
Detergent SQP (cable
breakage)
Where applicable, pump back-pressure too high: Check hydraulic
lines, where applicable, rinse.
Check connecting cable.
Motor defective, change.
Malfunctions and troubleshooting
48MAN054003, Ver. 1-02.2024