Measuring and saving
Data Value Unit
Conductivity measurement:
Measuring range
0 - 99 mS/cm,
adjustable in increments
of - 0.1 (0.1 - 9.9)
- 1 (10 - 100)
mS/cm
Inductive measurement accuracy
± 10% of the set
conductivity value < 3,
± 2.5% of the set
conductivity value > 3
mS/cm
Conductive measurement accuracy
± 10% of the set conductivity value
Temperature measurement:
Measuring range
>0 - <100 °C
Accuracy
± 1% @25°C
Data memory:
Malfunction messages
Max. 250, including
date/time
Operating data
Daily report, 1 year
Environmental load
Data Value Unit
Noise pollution
< 70 dB(A)
Ambient conditions
Data Value Unit
Ambient temperature
max. 50 °C
Ambient humidity
(non-condensing)
max. 95 %
Maximum operating height
2.000 m
Nameplate
1
2
3
4
5
6
7
8
9
11
9
Fig. 26: Ecoplus EXN-II nameplate
1
Machine number
2
Machine name
3
Supply voltage
4
Power consumption
5
Noise pressure level
6
Protection class
7
Production code
8
Manufacturer
9
Year of manufacture
11
Data Matrix Code
Technical data
56MAN054003, Ver. 1-02.2024

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ecolab Ecoplus EXN-II and is the answer not in the manual?

Ecolab Ecoplus EXN-II Specifications

General IconGeneral
BrandEcolab
ModelEcoplus EXN-II
CategoryControl Unit
LanguageEnglish

Related product manuals