EasyManua.ls Logo

Ecolab Ecoplus EXN-II - Measurement, Environmental, and Ambient Data

Ecolab Ecoplus EXN-II
204 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Measuring and saving
Data Value Unit
Conductivity measurement:
Measuring range
0 - 99 mS/cm,
adjustable in increments
of - 0.1 (0.1 - 9.9)
- 1 (10 - 100)
mS/cm
Inductive measurement accuracy
± 10% of the set
conductivity value < 3,
± 2.5% of the set
conductivity value > 3
mS/cm
Conductive measurement accuracy
± 10% of the set conductivity value
Temperature measurement:
Measuring range
>0 - <100 °C
Accuracy
± 1% @25°C
Data memory:
Malfunction messages
Max. 250, including
date/time
Operating data
Daily report, 1 year
Environmental load
Data Value Unit
Noise pollution
< 70 dB(A)
Ambient conditions
Data Value Unit
Ambient temperature
max. 50 °C
Ambient humidity
(non-condensing)
max. 95 %
Maximum operating height
2.000 m
Nameplate
1
2
3
4
5
6
7
8
9
11
9
Fig. 26: Ecoplus EXN-II nameplate
1
Machine number
2
Machine name
3
Supply voltage
4
Power consumption
5
Noise pressure level
6
Protection class
7
Production code
8
Manufacturer
9
Year of manufacture
11
Data Matrix Code
Technical data
56MAN054003, Ver. 1-02.2024

Table of Contents