EasyManua.ls Logo

Ecom j2kn pro - Page 53

Ecom j2kn pro
54 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ecom-J2KN
pro
Page 53
Data transfer ecom
-
J2KN
pro
to PC (USB)
The transfer occurs with 1200 - 38400 BAUD; 1 stop bit; no parity (ANSI character set)
CR / LF is send after each data record
Column
Description
Length
1-5 Storage number 5
6-7 Hour 2
8-9 Minute 2
10-11 Day 2
12-13 Month 2
14 Fuel type number (0 – 9) 1
15-19 T.Air in °C or °F 5
20-24 T.Gas in °C or °F 5
25-29 O
2
in vol.% (without comma) 5
30-34 CO in ppm 5
35 Draught (sign / - = minus; blank character = plus) 1
36-39 Draught in Pa 4
40 Oil trace (0 = no; 1 = yes 1
41 Soot 3 1
42 Soot 2 1
43 Soot 1 1
44-48 free 5
49-53 NO in ppm 5
54-58 T.Boiler 5
59-78 20 character text (1st display line) 20
79-98 20 character text (2nd display line) 20
99-114 16 character text (3rd display line) 16
115-116 2 signs (HEX $80, $00) 2
117-121 O
2
(CO measurement) in vol.% (without comma) 5
122-126 CO (CO measurement) in ppm related to 0,0 vol.% O
2
5
127-131 free 5
132-136 free 5
137-141 free 5
142-146 free 5
147-151 free 5
152-156 O
2
(O
2
check) in vol.% (without comma) 5
157-161 CO (O
2
check) in ppm 5
162 Draught (O
2
check / sign / - = minus; blank character = plus)
1
163-166 Draught (O
2
check) in Pa 4
167-168 CR-LF (#13#10) 2
Data transfer PC to
ecom
-
J2KN
pro
(ANSI character set):
First send: $00 $01
Then send: 56 characters text
Then send: $80 $00
Once the
ecom
-
J2KN
pro
has processed the data,
it sends $FF back. If the data volume is too large,
it sends another byte back. If the data transfer should be terminated, so just 60 byte $00 need to
be sent to the instrument.