INSTALLER AND USER GUIDE FOR CROSS 90 DIRECT FLOW REVERSE OSMOSIS FILTER
This manual is the intellectual property of Ecoso. Copying and reprinng is prohibited. © 2023
3.4. FIRST TIME USE
1. Turn on the feed water valve (4).
2. Connect the machine to the power supply. When the machine is powered on, the buzzer will
sound for 0.1 seconds, and the four indicator and the indicator on the puried water faucet will
light up in turn (blue-violet-red) for 1 second;
3. The machine will automacally wash for 5 mins. During washing, the lter life indicators (2-4)
are constantly lit in blue, and the system indicator (1) ashes red. The main part of the water is
draining.
4. Flush for 30 mins aer washing. During ushing, the lters lifeme indicators (2-4) lights are
always on, and the system indicator (1) light ashes blue (or as an indicator (1) is also a water
quality indicator it ashes according to the present water quality situaon), faucet indicator (5)
is also ashes blue.
5. When washing, be sure to carefully check the ghtness of all parts of the product, wipe the
connecon points with a paper ssue to see if the paper ssue is wet. Check whether the water
pipes are installed correctly and completely.
6. When the ushing is complete, turn o the puried water faucet and make sure that the faucet
does not leak, then the machine debugging is completed.
7. Aer washing, the whole machine enters the normal water-making state, and the system
indicator (1) and faucet indicator (5) are always blue during water supply . At this me, if you have
no need for water, turn o the faucet.
VERIFICATION OF THE UNIT’S OPERATING PARAMETERS
1. Measure recovery (proporon of supply water that becomes puried). You will need 1 L (1
quart) measuring cup and a stopwatch.
Open faucet (3) and measure me that the unit takes to produce 1 L (1 quart) of permeate
(puried water), then close faucet (3). Write down the result (tPermeate in the equaon below).
Disconnect the red tube connected to sink drain from drain saddle. Open faucet (3) and measure
me that the unit takes to produce 1 L (1 quart) of concentrate (waste water), then close faucet
3. Write down the result (tConcentrate in the equaon below). Calculate recovery using formula:
Where t is the number of seconds to obtain 1 L (1 quart) of water, R is recovery.
4. STEPS AFTER INSTALLATION
3. FILTER INSTALLATION