INSTALLER AND USER GUIDE FOR CROSS 90 DIRECT FLOW REVERSE OSMOSIS FILTER
This manual is the intellectual property of Ecoso. Copying and reprinng is prohibited. © 2023
6. SANITIZATION OF REVERSE OSMOSIS FILTER
Necessary material:
• Filter housing 2.5” x 10” and connectors
• 3% hydrogen peroxide (1 l)
• Brush
• Single-use vinyl gloves
• Easy-rinse soap or detergent
• Sanizing spray
• Paper napkin
Carry out a sanizaon of the equipment aer lters replacement and connuous stand-by.
The water used during sanizaon must be potable water (from a public distribuon network
complying with the corresponding potability requirements). To do this, follow the steps below:
• Open faucet 3 and let water recirculate in order to renew the water inside the equipment.
• Close the inlet valve (4) and open faucet (3) to decrease the pressure in the equipment.
• Use single-use vinyl gloves to handle sanizing products.
• Remove the exhausted replacement lters for disposal and clean the inside of the housing and
the connecons with a brush (which must be kept clean and disinfected) together with Easy-to-
rinse soap or detergent (low-sudsing) and suitable for cleaning surfaces in contact with food.
Subsequently rinse the housings and connecons correctly ensuring that all traces of detergent
are removed.
• Change the lters and wash them as indicated in the corresponding secon 6.2. To sanize the
equipment, the lters must be inside their housings.
• Disconnect the inlet tube to the system marked as “Inlet”, and insert the Filter housing 2.5” x
10” with connectors between the feed water valve (4) and the system’s water “Inlet”.
• Once the assembly is installed, keep the feed water valve (4) closed. The Filter housing 2.5” x
10” must be empty.
• Pour 1 L of Hydrogen Peroxide into the Filter housing. Screw the samp correctly to its head.
• The feed water valve (4) and the faucet (3) must be closed. Connect the equipment to the
electrical supply.
• Open the feed water valve 4 and the faucet (3), allowing the system to start operang and
leng the Oxygenated Water suck into it. When rst poon of sanizing liquid (about 300 ml) will
run out close the faucet (3). At this me the enre circuit contains sanizing liquid.
• Aer 10 minutes open faucet (3) and let the water ow for 5 minutes.