42
Door Component Replacement Removal and Replacement
Inner Door, Outer Door Panel, Control Panel Cover, and Soap Dispenser
Tools Needed:
- Phillips Screwdriver - Flat Tip Screwdriver - Needle nose pliers
Step 1: Remove the Control Panel Cover
Remove the 8 top Philips head screws on the inner door
The door latch is loose at this point and can be set aside.
Disconnect the electrical connector for the control circuit boards
NOTE: If replacing the Control Panel Cover you will need to remove the screws securing the control
circuit boards to the panel.