device may specify fuse rangs to ensure correct operaon of the over-current
protecon device. Ensure that the fuse used is suitable for the starng currents given on
the motor rang plate.
The diameter of the outer sheath of the electrical supply cable must be within the range
7 mm to 10.5 mm. The cable must conform in size and colour coding with the local and
naonal electrical installaon regulaons. The temperature rang of the cable must be
70 °C or greater.
Table 9
Motor connecon details
Pump item number
Voltage
(V)
Frequency
(Hz)
Connecon details: refer to Figure
A37316903 (all) 50/60
Figure: Single-phase motors with Amphenol
connector: 220-240 V 50 Hz and 230-240 V 60 Hz
on page 23
A37315903, A37415903 (all) 50/60
Figure: Single-phase motors: 220-240 V 50 Hz
and 230-240 V 60 Hz on page 22
A37315981, A37415981
115 60
Figure: Single-phase motors: 100 V 50 Hz,
100-105 V 60 Hz and 115 V 60 Hz on page 22
230 60
Figure: Single-phase motors: 200 V 50 Hz,
200-210 V 60 Hz and 230 V 60 Hz on page 23
A37315904, A37415904
100 50
Figure: Single-phase motors: 100 V 50 Hz,
100-105 V 60 Hz and 115 V 60 Hz on page 22
100105 60
Figure: Single-phase motors: 100 V 50 Hz,
100-105 V 60 Hz and 115 V 60 Hz on page 22
200 50
Figure: Single-phase motors: 200 V 50 Hz,
200-210 V 60 Hz and 230 V 60 Hz on page 23
200210 60
Figure: Single-phase motors: 200 V 50 Hz,
200-210 V 60 Hz and 230 V 60 Hz on page 23
A37317984, A37325984 (all) 50/60
Figure: Motor voltage selecon: single-phase
motors, 110/200-240 V 50 Hz and
115-120/200-240 V 60 Hz on page 24
4.6.1 Amphenol version single-phase motors
When selecng the mang half of the amphenol connector, please ensure that it is
compable.
The protecve earth (ground) connecon is required to make rst and break last with
respect to the other connecons.
Connect the electrical supply cable to the appropriate pins as shown in Figure: Single-
phase motors with Amphenol connector: 220-240 V 50 Hz and 230-240 V 60 Hz on page
23.
Page 20
A37310880_V - Installaon

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Edwards E2M30 and is the answer not in the manual?

Edwards E2M30 Specifications

General IconGeneral
BrandEdwards
ModelE2M30
CategoryWater Pump
LanguageEnglish

Related product manuals