Remove the outlet nozzle and connect to the 3/4 inch BSP threaded hole.
Remove the outlet nozzle and replace it with an NW25 ange adaptor (available as
an oponal accessory, refer to Pump outlet adaptor on page 47) and then connect
to the NW25 ange.
4.10 Gas-ballast inlet connecon
The posion of the gas-ballast inlet is shown in Figure: General view of the pump on
page 11. The gas-ballast inlet has several lters (shown in Figure: Remove/replace the
gas-ballast lter on page 37) to trap any dust and debris if air is used as the gas-ballast
supply.
If using a dierent gas for the gas-ballast supply or to connect a valve to the gas-ballast
inlet:
1.
Remove the lters (as described in Clean the gas-ballast lter on page 36).
2.
Connect the gas supply or valve to the 1/4 inch BSP threaded hole.
4.11 Leak-test the system
Leaktest the system and seal any leaks found aer you have installed the pump, to
prevent leakage of substances out of the system and leakage of air into the system.