EasyManua.ls Logo

Edwards E2M80 - 5.13 Fault-Finding: Operational Issues

Edwards E2M80
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
A344-02-880 Issue J
Page 34 © Edwards Limited 2007. All rights reserved.
Edwards and the Edwards logo are trademarks of Edwards Limited.
Maintenance
5.13.3 The pump is noisy
z The motor fan-cover is damaged
z The motor bearings are worn
z The oil is contaminated with solid particles
z The motor coupling is loose
z A blade is sticking.
5.13.4 The pump is too hot
z The ambient temperature is too high
z The cooling-air supply is insufficient or is too hot
z The electrical supply voltage is too high
z The outlet-filter or the outlet pipeline is blocked
z The oil-level is too low
z Yo u hav e f i l led th e pump w i t h the w r o n g type o f o il
z The oil is contaminated
z The process gas is too hot or the throughput is too high.
5.13.5 The vacuum is not fully maintained after the pump is switched off
z The gas-ballast control is open
z Damaged or missing 'O' ring
z Anti-suckback valve faulty
z Shaft seals damaged
z Exhaust valve damaged
5.13.6 The pumping speed is poor
z The connecting pipelines are too small in diameter
z The connecting pipelines are too long
z The inlet-filter is blocked