Technical data
A541-11-880 Issue A
2Technical data
2.1 Technical data
Table 1 - General technical data
Type Characteristics Value Units
Dimensions (L x W x H) 450 x 230 x 275 mm
Mass (excluding packaging) 59 kg
Noise level (at ultimate) <55 dB (A)
General Vibration level at inlet <1.5 mm s
-1
Vibration to the floor (when docked) <0.05 mm s
-1
Initial force to push the pump 0.06 kN
Sustained force to push the pump 0.04 kN
Warm up time to nominal pumping performance 45 minutes
Performance
Typical peak pumping speed (no gas purge/cold
pump)
110
65
m
3
h
-1
cfm
Ultimate pressure 0.01
8
mbar
mTorr
Connections
Pump inlet flange ISO63/NW50
Exhaust gas outlet NW25
Table 2 - General technical data
Item Description Rating Units
Operating conditions
Intended use Indoor use
Ambient temperature
range:
Operating 5 to 40 °C
Storage -45 to 55 °C
Maximum relative
humidity:
80% for temperatures up to 31 °C decreasing linearly to
50% relative humidity at 40 °C
Maximum operating
altitude
Up to 2000 m
Pollution degree II (IEC 61010) (Normally only non-conductive pollution
occurs. Occasionally, however, temporary conductivity
caused by condensation must be expected)
Atmosphere Non flammable and non-corrosive
Materials in contact
with process gas
Pump, shafts and rotors Cast iron, SG iron, aluminium and steel
Seals PTFE, Methacrylate Ester and Fluoroelastomer
Gas system Stainless steel, aluminium, PTFE and fluoroelastomer
Degree of protection
provided by enclosure
Enclosure protection
when installed
IP31D (EN60529: Degrees of protection provided by
enclosures)

Table of Contents