7.4 Clean the external fan grill
If the f
an cover is not kept clean, the air ow over the pump can be restricted and the
pump may overheat.
To clean the fan grill:
1. Switch o the pump and disconnect from the electrical supply.
2. Use a dry cloth and a so brush to remove dirt and deposits on the fan cover.
7.5 Replace the pump bearings
The service indicator, (ashing ON 3 sec/OFF 1 sec) is acvated to indicate that a bearing
replacement service interval has been reached. Bearing wear cannot always be detected
under normal operang condions. This service interval is a recommendaon that a
bearing replacement is required and is useful in the preventave maintenance plan.
Note:
F
ailure to replace the pump bearings on me can damage the pumping mechanism.
To reset the service indicator, refer to Table: Service indicator codes.
Bearing replacement is not possible by the customer, the pump must be returned to a
Service Technology Centre for maintenance.
7.6 Replace the pump controller
The service indicator, (ashing ON 3s / OFF 3s) is acvated to indicate that the pump
controller must be replaced. Contact us for further details.
To reset the service indicator, refer to Table: Service indicator codes.
Controller replacement is not possible by the customer, the pump must be returned to a
Service Technology Centre for maintenance.
7.7 Electrical safety check
Test the earth connuity and the insulaon resistance of the pump system in accordance
with local regulaons for the periodic test of electrical equipment.
The earth connuity must be less than 0.1 Ω and the DC insulaon resistance greater
than 1.0 MΩ. If the pump fails any of these tests, contact us or the supplier.
7.8 Service indicator codes
The nXRi controller has a service indicator, refer to Figure: Interface control panel. The
service indicator will ash a specic code whenever a service interval is reached. See
Table: Service indicator codes for service levels.
Table 16
Service indicator codes
Service ash c
ode Comments
ON 3s/OFF 1s Pump bearing service
ON 3s/OFF 3s Pump controller service
05/2021 - ©Edwards Limited
Page 40A90301880_C
A90301880_C - Maintenance and service