CET Electric Technology
48
Active/Return
16
1 / 0
Over Voltage THD Setpoint Active/Return
17
1 / 0
Over Voltage TOHD Setpoint Active/Return
18
1 / 0
Over Voltage TEHD Setpoint Active/Return
19
1 / 0
Over Current THD Setpoint Active/Return
20
1 / 0
Over Current TOHD Setpoint Active/Return
21
1 / 0
Over Current TEHD Setpoint Active/Return
22
1 / 0
Over Voltage Unbalance Setpoint
Active/Return
23
1 / 0
Over Current Unbalance Setpoint
Active/Return
24
1 / 0
Reversal Phase Setpoint Active/Return
25~40
Reserved
41
1 / 0
Under Uln Setpoint Active/Return
42
1 / 0
Under Ull Setpoint Active/Return
43
1 / 0
Under Current Setpoint Active/Return
44
1 / 0
Under In (calculated) Setpoint
Active/Return
45
1 / 0
Under Frequency Setpoint Active/Return
46
1 / 0
Under kW Total Setpoint Active/Return
47
1 / 0
Under kvar Total Setpoint Active/Return
48
1 / 0
Under kVA Total Setpoint Active/Return
49
1 / 0
Under PF Total Setpoint Active/Return
50
1 / 0
Under kW Total Present Demand Setpoint
Active/Return
51
1 / 0
Under kvar Total Present Demand Setpoint
Active/Return
52
1 / 0
Under kVA Total Present Demand Setpoint
Active/Return
53
1 / 0
Under kW Total Predicted Demand Setpoint
Active/Return
54
1 / 0
Under kvar Total Predicted Demand
Setpoint Active/Return
55
1 / 0
Under kVA Total Predicted Demand Setpoint
Active/Return
56
1 / 0
Under Voltage THD Setpoint Active/Return
57
1 / 0
Under Voltage TOHD Setpoint Active/Return
58
1 / 0
Under Voltage TEHD Setpoint Active/Return
59
1 / 0
Under Current THD Setpoint Active/Return
60
1 / 0
Under Current TOHD Setpoint
Active/Return
61
1 / 0
Under Current TEHD Setpoint Active/Return
62
1 / 0
Under Voltage Unbalance Setpoint
Active/Return
63
1 / 0
Under Current Unbalance Setpoint
Active/Return
4=Self-
diagnosis
1
1
-
System Parameter Fault
2
1
Internal Parameter Fault
3
Reserved
4
1
Memory Fault
5=Operations
1
0
Power On
2
0
Power Off
3
0
Clear 3-Ø Total and Per-Phase Energy
Registers via Front Panel
1
4
0
Reserved
5
0
Clear Maximum Demand Log of This Month
(Since Last Reset) via the Front Panel
6
0
Reserved
7
0
Clear Present Max./Min. (Since Last Reset)
via Front Panel
8
0
Reserved
9
0
Clear All Data via Front Panel
1
10
0
Clear SOE Log via Front Panel
11
0
Reserved
12
0
Clear All Pulse Counter via Front Panel
13
0
Clear Device Operating Time via Front Panel
14
0
Set Clock via Front Panel