TECHNICAL DATA
06/2020 21 NP-DK50 2V 50, 2x2V 110-A-5_06-2020-MD
Working pressure 8 – 10
bar
DK50 2V/50
DK50 2V/50S
DK50 2V/50/M
Nominal voltage
Frequency
a)
V, Hz
230, 50
230, 50
230, 50
Capacity at 8 bar
(FAD)
l/min
110
110
90
Working
pressure
b)
bar
8.0 – 10.0
8.0 – 10.0
8.0 – 10.0
Max. current
A
8.4
8.6
7.6
Motor power
kW
1.2
1.2
1.2
Air tank volume
l
50
50
50
Air quality -
filtration
m
-
-
0.3
Maximum
operating
pressure of safety
valve
bar
12.0
12.0
12.0
Noise level at 5
bar (L
pA
)
dB
≤67.0
≤51.5
≤72.2
Operating mode
%
S1-100
S1-100
S1-100
PDP drying at
7 bar
°C
-
-
≤ +3
Time to fill air tank
from 0 to 7 bar
s
305
305
226
Dimensions (net)
w x d x h
mm
577x587x804
750x715x1015
585x578x781
Net weight
kg
58
108
61
a)
State the compressor variant in the order
b)
For other range of pressure consult with the supplier
c)
Weight value is only informative data and applies only to a product without any accessories
Dependence of compressor capacity on working pressure