INSTALLATION
NP-DK50 2V 50, 2x2V 110-A-5_06-2020-MD 30 06/2020
Fig. 6: DK50 2V/50S
A
B
C
10.4. Installation of condensate drain valve on cabinet (DK50 2x2V/110)
For compressor variant with cabinet install the drain cock (1) into a hole on the side of the cabinet
and install a tube PA Ø8 / Ø6 (2). Insert the second end of the tube into the fitting (4) under the air
tank; the valve (3) with the tube shall be dismantled from this fitting.
Blind the hole with a plug Ø16.5 at the opposite side.
The drain cock is part of the cabinet basic equipment. The condensate drain valve can be mounted
on any side of the compressor cabinet.
Fig. 7: Installation of condensate drain valve on cabinet