ELECTRO FREEZE Shake Model CS705
184592
26
9 Daily Procedures
9.1.1 General Cleaning
1. Remove the spinner flex shaft
cover assembly (1) in preparation to
disassemble the shake mix chamber (9).
SAFETY NOTE: Removal of the flex
shaft cover disables the spinner motor.
2. Disconnect the syrup lines and
water rinse line from the mix chamber.
3. Remove the mix chamber and
set aside for cleaning.
4. Disconnect the flex-shaft from
the spinner shaft (taking care not to drop
the spinner shaft which will fall out of the
plunger), remove the spinner shaft from
the shake head.
5.
Prepare a container of
sanitizing solution.
Sanitizing solution
must be mixed according to
manufacturer’s instructions to yield 100
PPM strength chlorine solution.
(example: Stera-Sheen Green Label).
Use warm water (100-110°F or 37-
43°C). Fill the wash bottle with sanitizing
solution.
6. Using a brush and bottle of sanitzing
solution wash down the bottom of the shake
head and plunger, being sure to clean the
plunger spinner shaft hole with a brush.
7. Using the bottle of sanitizing solution.
a. rinse down the head, end of the
plunger, and plunger spinner shaft hole
c. spray out the ends of each syrup
line connector. Also spray the end of the
connector for the water line.
d. wash the mix chamber using a
brush to clean the center bore as well as
each of the syrup holes.
e. wash the spinner shaft using a
brush to clean the paddle holes.
f. rinse off the cleaned mix
chamber and spinner shaft with clean
sanitzing solution.
8. Set parts aside to dry.
9. Leave shake mix system dis-
assembled overnight and re-assemble prior
to the next use. See Assembly Section 7.
10. If your location is open 24 hours,
system must be cleaned once a day, we
recommend cleaning steps 1 through 11 in
the morning or other slow period.
Figure 9-1
9.1 Night or Idle Operation