Programming and Configuration Manual
47
EXTENDED PROGRAMMING
Possibility to change drum rotation parameters. (Only valid for machines with reversing drum).
• OVERRIDE MOTOR ACTION
• REVERSING (only visible if OVERRIDE MOTOR ACTION is set to YES)
• MOTOR CLOCKWISE (only visible if OVERRIDE MOTOR ACTION is set to YES)
• MOTOR REVERSING (only visible if OVERRIDE MOTOR ACTION is set to YES)
• PAUSE BETWEEN REV. (only visible if OVERRIDE MOTOR ACTION is set to YES)
OVERRIDE MOTOR ACTION
YES = Program will use the values for motor action set in the following parameters for all drying modules and cooling.
The following parameters are only visible if OVERRIDE MOTOR ACTION is set to YES.
NO = Pre-set values will be used.
REVERSING
YES = Drum reversing.
NO = No drum reversing.
MOTOR CLOCKWISE
Set the time that the drum shall rotate clockwise before pause.
MOTOR REVERSING
Set the time that the drum shall rotate counter clockwise before pause.
PAUSE BETWEEN REV.
Set the time for pause between the rotation cycles (MOTOR CLOCKWISE and MOTOR REVERSING)
PRE-DRYING, MAIN-DRYING and END-DRYING
• MAX INLET AIR TEMP.
• MAX OUTLET AIR TEMP.
• END VALUE RMC
• END TEMPERATURE
• MODULE TIME
Note!
All parameters are shown, but in a time program/coin program PRE-DRYING and END-DRYING are not used.
MAX INLET AIR TEMP.
Adjust the inlet air temperature.
MAX OUTLET AIR TEMP.
Adjust the outlet air temperature.
END VALUE RMC
Adjust the RMC end value.
END TEMPERATURE
Adjust the end temperature.
MODULE TIME
Adjust the module time.
COOLING
• OUTLET AIR TEMP.
• COOLING TIME