90
Condenser 600mm freezer model:
Condenser 900mm refrigerated model:
Condenser 900mm freezer model:
D.1.2.2 Replacing the power cable
To replace the power cable, proceed as follows:
disconnect the power supply;
undo the control panel xing screws;
lift the control panel and make sure it is locked (it is ad-
visable to x it with adhesive tape);
remove the electrical box plastic cover;
replace the power cable;
ret the electrical box plastic cover and lower the con-
trol panel;
retighten the control panel xing screws;
reconnect the power supply.
D.1.2.3 Quick troubleshooting guide
In some cases, faults can be eliminated easily and quickly by
following a brief troubleshooting guide:
A. The appliance does not switch on:
make sure the plug is properly inserted in power socket.
make sure the socket is powered.
B. The inside temperature is too high:
check the thermostat setting;
make sure there is no heat source near the appliance;
make sure the door closes properly.
C. The appliance is too noisy:
make sure the appliance is properly levelled.
An unbalanced position can set o vibrations.
make sure the appliance is not touching other equipment
or parts which could reverberate.
If the fault persists after carrying out the above checks, contact
the After-Sales Service, remembering to specify:
the type of fault;
the appliance PNC (production number code);
the Ser. No. (appliance serial number).
Note: The code and serial number are essential for iden-
tifying the type of appliance and date of manufacture:
appliance identication code
fourth digit of the year
of production (2014)
third digit of the year
of production (2014)
week 14
10th piece
manufactured
in the week
Ser. No. 4 14 1 0010
PNC
691199 00