Pre-set agitator programs
There are 4 fixed agitator programs and 5 spaces for
customised programs (adjustable).
• Press Increase speed once.
The following text appears in the display:
PRESET AG.PROGR
WITHOUT GRID
SPD TIME R PAUSE
XXX XX:XX X XX:XX
• Press Increase speed until an appropriate program
appears in the display.
• Press Agitator start . The agitator starts the selec-
ted program.
• The agitator stops automatically at the end of the pro-
gram.
• The speed can be changed within each program.
• The agitator can also be stopped with Agitatorstop .
Fixed agitator programs
WITHOUT GRID
The fixed program WITHOUT GRID is used in order for
the agitator to rotate when the grid is open and with the
pan tilted.
• Press Increase speed until WITHOUT GRID pro-
gram appears in the display:
PRESET AG.PROGR
WITHOUT GRID
SPD TIME R PAUSE
XXX XX:XX X XX:XX
• Press Agitator start .
• Press Agitator start and keep pressed, and the agi-
tator tool will rotate at 15 rpm.
• Press Agitator stop to stop the program.
Mix
The fixed program MIX is used in order to mix the thicker
consistence products e.g. minced meat (ground meat). Go
and pause time are shorter than normal agitator program
with pause.
• Press Increase speed until Mix program appears in
the display:
PRESET AG.PROGR
MIX
SPD TIME R PAUSE
XXX XX:XX X XX:XX
Agitator
NOTE! When the agitator rotates
• The measuring stick must not be in the pan
• Do not insert the measuring stick down into the pan
• Do not insert any instruments down into the pan
• Do not use the pan columns as work surfaces
• Do not taste!
In order to start the agitator, the grid must be closed. Wit-
hout the grid, the following text appears in the display:
AGITATOR
GRID ON
There are 2 pre-set fixed agitator programs which are
exempted from this function (see pre-set agitator pro-
grams).
Continuous stirring
• Press Agitator start once. The left LED comes on
and glows steadily.
• Press Increase speed and the agitator starts at the
lowest speed of 20 rpm. (Max. speed 100 rpm.)
• Press Decrease speed to reduce the speed.
• Press Agitator stop to stop the agitator.
Reversing agitation
• Press Agitator start twice. The central LED lights
up.
• Press Increase speed once and the agitator starts
at the lowest speed of 20 rpm (Max. speed 100 rpm.)
The agitator rotates for 15 seconds clockwise, pauses
for 5 seconds, then rotates for 15 seconds anti-clockwi-
se, etc.
• Press Decrease speed to reduce the speed.
• Press Agitator stop to stop the agitator.
Changing pause time
The pause time during agitation can be changed when the
central LED on Agitator start is lit:
• Press Agitator start and the right LED will light up
as well.
The following text appears in the display:
PAUSE TIME Xmin XXs
• Press Increase value to enter a longer pause in
the agitation. (Max. 9 min 55 s and min. 0 min 05 s).