34
Alarm Description Possible fault Action/machine status Reset
E61 Insufficient heating during washing
NTC sensor faulty; heating element faulty; wiring faulty; PCB
faulty.
The heating phase is skipped ---
E62 Overheating during washing
NTC sensor faulty; heating element faulty; wiring faulty; PCB
faulty.
Safety drain cycle – Cycle stopped
with door open
OFF
E66 Heating element power relay faulty
PCB faulty; current leakage from heating element to ground.
Safety drain cycle – Cycle stopped
with door open
OFF
E71 Washing NTC sensor faulty
NTC sensor faulty; wiring faulty; PCB faulty. The heating phase is skipped Start
E82 Error in selector reset position
PCB faulty. --- OFF
E83 Error in reading selector
Incorrect configuration data; PCB faulty. Cycle cancelled ---
E93 Incorrect configuration of appliance
Incorrect configuration data; PCB faulty. Cycle interrupted OFF
E94 Incorrect configuration of washing cycle
Incorrect configuration data; PCB faulty. Cycle interrupted OFF
E95
Communications error between
microprocessor and EEPROM
PCB faulty. Cycle interrupted OFF
E96
Incongruency between hardware version
and configuration
Incorrect configuration data; PCB faulty. Cycle interrupted OFF
E97
Incongruency between selector and cycles
configuration
Incorrect configuration data; PCB faulty. Cycle interrupted OFF
EB1 Frequency of appliance incorrect
Power supply problems (incorrect / disturbance); PCB faulty. Cycle interrupted ---
EB2 Voltage too high
Power supply problems (incorrect / disturbance); PCB faulty. Cycle interrupted ---
EB3 Voltage too low
Power supply problems (incorrect / disturbance); PCB faulty. Cycle interrupted ---